MC9S12XDT512CAA Freescale, MC9S12XDT512CAA Datasheet - Page 144

no-image

MC9S12XDT512CAA

Manufacturer Part Number
MC9S12XDT512CAA
Description
Manufacturer
Freescale
Datasheet

Specifications of MC9S12XDT512CAA

Cpu Family
HCS12
Device Core Size
16b
Frequency (max)
40MHz
Interface Type
CAN/I2C/SCI/SPI
Total Internal Ram Size
32KB
# I/os (max)
59
Number Of Timers - General Purpose
12
Operating Supply Voltage (typ)
2.5/5V
Operating Supply Voltage (max)
2.75/5.5V
Operating Supply Voltage (min)
2.35/3.15V
On-chip Adc
8-chx10-bit
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
80
Package Type
PQFP
Program Memory Type
Flash
Program Memory Size
512KB
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12XDT512CAA
Manufacturer:
FREESCALE
Quantity:
2 235
Part Number:
MC9S12XDT512CAA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S12XDT512CAA
Manufacturer:
FREESCALE
Quantity:
2 235
Part Number:
MC9S12XDT512CAAR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Chapter 4 Analog-to-Digital Converter (ATD10B16CV4) Block Description
144
CC[3:0}
FIFOR
Field
3:0
4
FIFO Over Run Flag — This bit indicates that a result register has been written to before its associated
conversion complete flag (CCF) has been cleared. This flag is most useful when using the FIFO mode because
the flag potentially indicates that result registers are out of sync with the input channels. However, it is also
practical for non-FIFO modes, and indicates that a result register has been over written before it has been read
(i.e., the old data has been lost). This flag is cleared when one of the following occurs:
0 No over run has occurred
1 Overrun condition exists (result register has been written while associated CCFx flag remained set)
Conversion Counter — These 4 read-only bits are the binary value of the conversion counter. The conversion
counter points to the result register that will receive the result of the current conversion. For example, CC3 = 0,
CC2 = 1, CC1 = 1, CC0 = 0 indicates that the result of the current conversion will be in ATD Result Register 6.
If in non-FIFO mode (FIFO = 0) the conversion counter is initialized to zero at the begin and end of the
conversion sequence. If in FIFO mode (FIFO = 1) the register counter is not initialized. The conversion
counters wraps around when its maximum value is reached.
Aborting a conversion or starting a new conversion by write to an ATDCTL register (ATDCTL5-0) clears the
conversion counter even if FIFO=1.
• Write “1” to FIFOR
• Start a new conversion sequence (write to ATDCTL5 or external trigger)
Table 4-18. ATDSTAT0 Field Descriptions (continued)
MC9S12XDP512 Data Sheet, Rev. 2.21
Description
Freescale Semiconductor

Related parts for MC9S12XDT512CAA