MC9S12XDT512CAA Freescale, MC9S12XDT512CAA Datasheet - Page 337

no-image

MC9S12XDT512CAA

Manufacturer Part Number
MC9S12XDT512CAA
Description
Manufacturer
Freescale
Datasheet

Specifications of MC9S12XDT512CAA

Cpu Family
HCS12
Device Core Size
16b
Frequency (max)
40MHz
Interface Type
CAN/I2C/SCI/SPI
Total Internal Ram Size
32KB
# I/os (max)
59
Number Of Timers - General Purpose
12
Operating Supply Voltage (typ)
2.5/5V
Operating Supply Voltage (max)
2.75/5.5V
Operating Supply Voltage (min)
2.35/3.15V
On-chip Adc
8-chx10-bit
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
80
Package Type
PQFP
Program Memory Type
Flash
Program Memory Size
512KB
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MC9S12XDT512CAA
Manufacturer:
FREESCALE
Quantity:
2 235
Part Number:
MC9S12XDT512CAA
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
Part Number:
MC9S12XDT512CAA
Manufacturer:
FREESCALE
Quantity:
2 235
Part Number:
MC9S12XDT512CAAR
Manufacturer:
Freescale Semiconductor
Quantity:
10 000
7.3.2.19
Read: Anytime
Write: Anytime
All bits reset to zero.
Freescale Semiconductor
MCPR[1:0]
MODMC
RDMCL
Reset
MCEN
ICLAT
FLMC
Field
MCZI
1:0
7
6
5
4
3
2
W
R
MCZI
Modulus Counter Underflow Interrupt Enable
0 Modulus counter interrupt is disabled.
1 Modulus counter interrupt is enabled.
Modulus Mode Enable
0 The modulus counter counts down from the value written to it and will stop at 0x0000.
1 Modulus mode is enabled. When the modulus counter reaches 0x0000, the counter is loaded with the latest
Note: For proper operation, the MCEN bit should be cleared before modifying the MODMC bit in order to reset
Read Modulus Down-Counter Load
0 Reads of the modulus count register (MCCNT) will return the present value of the count register.
1 Reads of the modulus count register (MCCNT) will return the contents of the load register.
Input Capture Force Latch Action — When input capture latch mode is enabled (LATQ and BUFEN bit in
ICSYS are set), a write one to this bit immediately forces the contents of the input capture registers TC0 to TC3
and their corresponding 8-bit pulse accumulators to be latched into the associated holding registers. The pulse
accumulators will be automatically cleared when the latch action occurs.
Writing zero to this bit has no effect. Read of this bit will always return zero.
Force Load Register into the Modulus Counter Count Register — This bit is active only when the modulus
down-counter is enabled (MCEN = 1).
A write one into this bit loads the load register into the modulus counter count register (MCCNT). This also resets
the modulus counter prescaler.
Write zero to this bit has no effect. Read of this bit will return always zero.
Modulus Down-Counter Enable
0 Modulus counter disabled. The modulus counter (MCCNT) is preset to 0xFFFF. This will prevent an early
1 Modulus counter is enabled.
Modulus Counter Prescaler Select — These two bits specify the division rate of the modulus counter prescaler
when PRNT of TSCR1 is set to 0. The newly selected prescaler division rate will not be effective until a load of
the load register into the modulus counter count register occurs.
16-Bit Modulus Down-Counter Control Register (MCCTL)
0
7
value written to the modulus count register.
interrupt flag when the modulus down-counter is enabled.
the modulus counter to 0xFFFF.
Figure 7-41. 16-Bit Modulus Down-Counter Control Register (MCCTL)
MODMC
0
6
Table 7-22. MCCTL Field Descriptions
RDMCL
MC9S12XDP512 Data Sheet, Rev. 2.21
0
5
ICLAT
0
0
4
Description
FLMC
Chapter 7 Enhanced Capture Timer (S12ECT16B8CV2)
0
0
3
MCEN
0
2
MCPR1
0
1
MCPR0
0
0
337

Related parts for MC9S12XDT512CAA