PEB2256H-V12 Infineon Technologies, PEB2256H-V12 Datasheet - Page 394

no-image

PEB2256H-V12

Manufacturer Part Number
PEB2256H-V12
Description
IC INTERFACE LINE 3.3V 80-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB2256H-V12

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
80-SQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB2256H-V12
PEB2256H-V12IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2256H-V12
Manufacturer:
Infineon Technologies
Quantity:
10 000
RFT13, RFT03
Common Configuration Register 5 (Read/Write)
Value after reset: 00
CCR5
SUET
CSF
Data Sheet
7
RFIFO3 Threshold Level - HDLC Channel 3
The size of the accessible part of RFIFO3 can be determined by
programming these bits. The number of valid bytes after an RPF
interrupt is given in the following table:
RFT13
0
0
1
1
The value of RFT13/03 can be changed dynamically if reception is not
running or after the current data block has been read, but before the
command CMDR4.RMC3 is issued (interrupt controlled data
transfer).
Note: SUET, CSF and AFX are only valid, if SS7 mode is selected.
Signaling Unit Error Threshold - HDLC Channel 1
Defines the number of signaling units received in error that will cause
an error rate high indication (ISR1.SUEX).
0 =
1 =
Compare Status Field - HDLC Channel 1
If the status fields of consecutive LSSUs are equal, only the first is
stored and every following is ignored.
0 =
1 =
H
Threshold 64 errored signaling units
Threshold 32 errored signaling units
Compare disabled.
Compare enabled.
CR and EPR are only valid, if PPR mode is selected.
SUET
RFT03
0
1
0
1
CSF
Size of Accessible Part of RFIFO3
32 bytes (default value)
16 bytes
4 bytes
2 bytes
394
AFX
CR
T1/J1 Registers
FALC56 V1.2
EPR
0
PEB 2256
2002-08-27
(8D)

Related parts for PEB2256H-V12