CY7C63413-PVXC Cypress Semiconductor Corp, CY7C63413-PVXC Datasheet - Page 21

CY7C63413-PVXC

Manufacturer Part Number
CY7C63413-PVXC
Description
Manufacturer
Cypress Semiconductor Corp
Datasheet

Specifications of CY7C63413-PVXC

Cpu Family
enCoRe II
Device Core
M8C
Device Core Size
8b
Frequency (max)
12MHz
Interface Type
USB
Program Memory Type
EPROM
Program Memory Size
8KB
Total Internal Ram Size
256Byte
# I/os (max)
24
Number Of Timers - General Purpose
1
Operating Supply Voltage (typ)
5V
Operating Supply Voltage (max)
5.25/5.5V
Operating Supply Voltage (min)
4/4.35V
Instruction Set Architecture
RISC
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Mounting
Surface Mount
Pin Count
48
Package Type
SSOP
Lead Free Status / Rohs Status
Compliant
Document #: 38-08027 Rev. *B
Truth Tables
Table 28.USB Register Mode Encoding
The ‘In’ column represents the SIE’s response to the token
type.
A disabled endpoint will remain such until firmware changes it,
and all endpoints reset to disabled.
Any Setup packet to an enabled and accepting endpoint will
be changed by the SIE to 0001 (NAKing). Any mode which
indicates the acceptance of a Setup will acknowledge it.
Most modes that control transactions involving an ending ACK
will be changed by the SIE to a corresponding mode which
NAKs follow on packets.
Mode
Disable
Nak In/Out
Status Out Only
Stall In/Out
Ignore In/Out
Isochronous Out
Status In Only
Isochronous In
Nak Out
Ack Out
Nak Out - Status In
Ack Out - Status In
Nak In
Ack In
Nak In - Status Out
Ack In - Status Out
Encoding
0000
0001
0010
0100
0101
1000
1001
1010
0011
0110
0111
1011
1100
1101
1110
1111
accept
accept
accept
accept
accept
accept
accept
accept
accept
ignore
ignore
ignore
ignore
ignore
ignore
ignore
Setup
TX cnt
TX cnt
TX cnt
ignore
ignore
ignore
ignore
ignore
NAK
TX 0
TX 0
TX 0
NAK
NAK
stall
stall
In
always
Check
ignore
ignore
ignore
ignore
ignore
check
check
NAK
NAK
ACK
NAK
ACK
stall
stall
Out
A Control endpoint has three extra status bits for PID (Setup,
In and Out), but must be placed in the correct mode to function
as such. Also a non-Control endpoint can be made to act as a
Control endpoint if it is placed in a non appropriate mode.
A ‘check’ on an Out token during a Status transaction checks
to see that the Out is of zero length and has a Data Toggle
(DTOG) of 1.
Ignore all USB traffic to this endpoint
Forced from Set-up on Control endpoint, from modes other
than 0000
For Control endpoints
For Control endpoints
For Control endpoints
Available to low speed devices, future USB spec
enhancements
For Control Endpoints
Available to low speed devices, future USB spec
enhancements
An ACK from mode 1001 --> 1000
This mode is changed by SIE on issuance of ACK --> 1000
An ACK from mode 1011 --> 1010
This mode is changed by SIE on issuance of ACK --> 1010
An ACK from mode 1101 --> 1100
This mode is changed by SIE on issuance of ACK --> 1100
An ACK from mode 1111 --> 1110 NAck In - Status Out
This mode is changed by SIE on issuance of ACK -->1110
Comments
CY7C63413C
CY7C63513C
CY7C63613C
Page 21 of 32
[+] Feedback

Related parts for CY7C63413-PVXC