UPD78F1211MC-GAA-AX Renesas Electronics America, UPD78F1211MC-GAA-AX Datasheet - Page 394

no-image

UPD78F1211MC-GAA-AX

Manufacturer Part Number
UPD78F1211MC-GAA-AX
Description
MCU 16BIT 78K0R/LX3 38-SSOP
Manufacturer
Renesas Electronics America
Series
78K0R/Ix3r
Datasheet

Specifications of UPD78F1211MC-GAA-AX

Core Processor
78K/0R
Core Size
16-Bit
Speed
40MHz
Connectivity
3-Wire SIO, I²C, LIN, UART/USART
Peripherals
DMA, LVD, POR, PWM, WDT
Number Of I /o
27
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
7.5.2 Operation as real-time output function (type 2)
output trigger generation channel.
performed.
interval measurement.
a real-time output trigger by valid edge detection of the TIn pin input or setting 1 to the channel start trigger (TSn).
TOm by the real-time output trigger. The TCRn value is captured to TDRn at the INTTMn generation timing, but the
TDRn value is not used.
an up counter in the capture mode.
while TEn is 0 or when the valid edge of the TIn input is detected.
and TOn is toggled when MDn0 of the TMRn register is 1.
(captured) to TDRn, when the valid edge of the TIn pin input is detected or when the channel start trigger (TSn) is set
to 1.
channel.
is controlled by the TREm bit. The TOm output level will not change by only rewriting TROm.
output timing of the real-time output trigger generation channel. In the lower channel, TOm is not toggled at the
INTTMn output timing of the real-time output trigger generation channel when TREm = 0 or TRCm = 1.
operated as different functions.
392
The values of TROn and TROm can be output from TOn and TOm by using the INTTMn output of the real-time
The real-time output function (type 2) is an extension of the function described in 6.7.4 Operation as input pulse
The real-time output trigger generation channel (channel to which TRCn = 1 is set) outputs INTTMn and generates
The real-time output channel (channels to which TRCm = 0, TRE = 1 are set) outputs the set value of TROm from
The channel to which TRCn = 1 was set becomes the real-time output trigger generation channel and operates as
TCRn starts counting up from 0000H along with the count clock, when the channel start trigger (TSn) is set to 1
At this time, INTTMn is not output and TOn is not toggled when MDn0 of the TMRn register is 0. INTTMn is output
The counter (TCRn) is cleared to 0000H and INTTMn is output at the same time the count value is transferred
The set value of TROn is output from TOn at the INTTMn output timing of the real-time output trigger generation
TOm of the lower channel (real-time output channel) of the real-time output trigger generation channel (TRCn = 1)
When TREm of the real-time output channel (TRCm = 0) is 1, TOm outputs the set value of TROm at the INTTMn
When the real-time output function (type 2) is used, TCRm, TDRm, and INTTMn of the lower channel can be
Remark n = 01 to 10 (78K0R/IB3: n = 01 to 07)
m = 02 to 11 (78K0R/IB3: m = 02 to 07)
CHAPTER 7 INVERTER CONTROL FUNCTIONS
Real-time output by external pin input edge detection or software can be
User’s Manual U19678EJ1V1UD

Related parts for UPD78F1211MC-GAA-AX