AT91SAM7S64C-AU Atmel, AT91SAM7S64C-AU Datasheet - Page 306

IC ARM7 MCU 32BIT 64K 64LQFP

AT91SAM7S64C-AU

Manufacturer Part Number
AT91SAM7S64C-AU
Description
IC ARM7 MCU 32BIT 64K 64LQFP
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM7S64C-AU

Package / Case
64-LQFP
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Operating Temperature
-40°C ~ 85°C
Speed
55MHz
Number Of I /o
32
Core Processor
ARM7
Program Memory Type
FLASH
Ram Size
16K x 8
Program Memory Size
64KB (64K x 8)
Data Converters
A/D 8x10b
Oscillator Type
Internal
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Connectivity
I²C, SPI, SSC, UART/USART, USB
Core Size
16/32-Bit
Core
ARM7TDMI
Package
64LQFP
Device Core
ARM7TDMI
Family Name
AT91
Maximum Speed
55 MHz
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Number Of Programmable I/os
32
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Number Of Timers
3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
AT91SAM7S64B-AU::AT91SAM7S64B-AU

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S64C-AU
Manufacturer:
ATMEL
Quantity:
4 300
Part Number:
AT91SAM7S64C-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S64C-AU
Manufacturer:
ATMEL
Quantity:
1 005
Part Number:
AT91SAM7S64C-AU
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
AT91SAM7S64C-AU-999
Manufacturer:
Atmel
Quantity:
10 000
29.7.1
Register Name:
Access Type:
• START: Send a START Condition
0 = No effect.
1 = A frame beginning with a START bit is transmitted according to the features defined in the mode register.
This action is necessary when the TWI peripheral wants to read data from a slave. When configured in Master Mode with a
write operation, a frame is sent as soon as the user writes a character in the Transmit Holding Register (TWI_THR).
• STOP: Send a STOP Condition
0 = No effect.
1 = STOP Condition is sent just after completing the current byte transmission in master read mode.
• MSEN: TWI Master Transfer Enabled
0 = No effect.
1 = If MSDIS = 0, the master data transfer is enabled.
• MSDIS: TWI Master Transfer Disabled
0 = No effect.
1 = The master data transfer is disabled, all pending data is transmitted. The shifter and holding characters (if they contain
data) are transmitted in case of write operation. In read operation, the character being transferred must be completely
received before disabling.
• SWRST: Software Reset
0 = No effect.
1 = Equivalent to a system reset.
306
SWRST
– In single data byte master read, the START and STOP must both be set.
– In multiple data bytes master read, the STOP must be set after the last data received but one.
– In master read mode, if a NACK bit is received, the STOP is automatically performed.
– In multiple data write operation, when both THR and shift register are empty, a STOP condition is automatically
31
23
15
7
sent.
AT91SAM7S Series Preliminary
TWI Control Register
30
22
14
TWI_CR
Write-only
6
29
21
13
5
28
20
12
4
MSDIS
27
19
11
3
MSEN
26
18
10
2
STOP
25
17
9
1
6175K–ATARM–30-Aug-10
START
24
16
8
0

Related parts for AT91SAM7S64C-AU