XR17V358IB176-F Exar Corporation, XR17V358IB176-F Datasheet - Page 49

IC UART PCIE OCTAL 176FPBGA

XR17V358IB176-F

Manufacturer Part Number
XR17V358IB176-F
Description
IC UART PCIE OCTAL 176FPBGA
Manufacturer
Exar Corporation
Datasheet

Specifications of XR17V358IB176-F

Number Of Channels
1, UART
Package / Case
176-LFBGA
Features
*
Fifo's
256 Byte
Protocol
RS485
Voltage - Supply
1.2V, 3.3V
With Auto Flow Control
Yes
With Irda Encoder/decoder
Yes
With False Start Bit Detection
Yes
With Modem Control
Yes
Mounting Type
Surface Mount
Data Rate
25 Mbps
Supply Current
120 mA
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
Operating Supply Voltage
3.3 V
No. Of Channels
8
Uart Features
Tx/Rx FIFO Counters
Supply Voltage Range
3V To 3.6V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
BGA
No. Of Pins
176
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
1016-1296 - EVAL BOARD FOR XR17V358-E81016-1295 - EVAL BOARD FOR XR17V358-E41016-1293 - EVAL BOARD FOR XR17V358
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
1016-1294

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XR17V358IB176-F
Manufacturer:
EXAR
Quantity:
1 700
Part Number:
XR17V358IB176-F
Manufacturer:
Exar Corporation
Quantity:
10 000
Part Number:
XR17V358IB176-F
Manufacturer:
EXAR/艾科嘉
Quantity:
20 000
REV. 1.0.2
When FCR bit [0] equals a logic 1 for FIFO enable; resetting IER bits [3:0] enables the XR16V358 in the FIFO
polled mode of operation. Since the receiver and transmitter have separate bits in the LSR either can be used
in the polled mode by selecting respective transmit or receive control bit(s).
A. LSR BIT-0 indicates there is data in RHR (non-FIFO mode) or RX FIFO (FIFO mode).
B. LSR BIT-1 indicates an overrun error has occurred and that data in the FIFO may not be valid.
C. LSR BIT 2-4 provides the type of receive data errors encountered for the data byte in RHR, if any.
D. LSR BIT-5 indicates THR (non-FIFO mode) or TX FIFO (FIFO mode) is empty.
E. LSR BIT-6 indicates when both the transmit FIFO and TSR are empty.
F. LSR BIT-7 indicates a data error in at least one character in the RX FIFO.
IER[7]: CTS# Input Interrupt Enable (requires EFR bit [4]=1)
IER[6]: RTS# Output Interrupt Enable (requires EFR bit [4]=1)
IER[5]: Xoff Interrupt Enable (requires EFR bit [4]=1)
IER[4]: Reserved
IER[3]: Modem Status Interrupt Enable
The Modem Status Register interrupt is issued whenever any of the delta bits of the MSR register (bits [3:0]) is
set.
IER[2]: Receive Line Status Interrupt Enable
An Overrun error, Framing error, Parity error or detection of a Break character will result in an LSR interrupt.
The V358 will issue an LSR interrupt immediately after receiving a character with an error. It will again re-issue
the interrupt (if the first one has been cleared by reading the LSR register) when the character with the error is
on the top of the FIFO, meaning the next one to be read out of the FIFO.
For example, let’s consider an incoming data stream of 0x55, 0xAA, etc. and that the character 0xAA has a
Parity error associated with it. Let’s assume that the character 0x55 has not been read out of the FIFO yet. The
V358v358 will issue an interrupt as soon as the stop bit of the character 0xAA is received. The LSR register will
have only the FIFO error bit (bit [7]) set and none of the other error bits (bits [4:1]) will be set, since the byte on
the top of the FIFO is 0x55 which does not have any errors associated with it. When this byte has been read
out, the V358 will issue another LSR interrupt and this time the LSR register will show the Parity bit (bit [2]) set.
4.4.2
Logic 0 = Disable the CTS# interrupt (default).
Logic 1 = Enable the CTS# interrupt. The UART issues an interrupt when CTS# pin makes a transition from
LOW to HIGH.
Logic 0 = Disable the RTS# interrupt (default).
Logic 1 = Enable the RTS# interrupt. The UART issues an interrupt when RTS# pin makes a transition from
LOW to HIGH.
Logic 0 = Disable the software flow control, receive Xoff interrupt (default).
Logic 1 = Enable the software flow control, receive Xoff interrupt. See Software Flow Control section for
details.
Logic 0 = Disable the modem status register interrupt (default).
Logic 1 = Enable the modem status register interrupt.
Logic 0 = Disable the receiver line status interrupt (default).
Logic 1 = Enable the receiver line status interrupt.
IER versus Receive/Transmit FIFO Polled Mode Operation
49
HIGH PERFORMANCE OCTAL PCI EXPRESS UART
XR17V358