FS1A-C01S IDEC, FS1A-C01S Datasheet - Page 10

Safety Controller

FS1A-C01S

Manufacturer Part Number
FS1A-C01S
Description
Safety Controller
Manufacturer
IDEC
Datasheet

Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
In Logic 4, muting functions are added to the dual solid state output of Logic 3.
Dual direct-opening components such as
With a muting function, the system stops when detecting a human and temporarily defeats the light curtain while work
objects are being supplied. This improves the system’s productivity. Muting functions can be used easily by connecting the
light curtain, muting sensor, and muting lamp to the SafetyOne (Note). In muting status, the OFF signals of corresponding
safety solid state outputs are defeated.
Note 1: Use light curtain with a PNP output.
Note: Use light curtains, muting sensors, and muting lamps which meet the safety regulations or safety category of the country or regions where the
products are used. Otherwise safety cannot be ensured, resulting in possible danger.
10
The system stops when:
The system is equipped with light curtains, muting sensors, a muting
lamp, and emergency stop switches.
The system can operate when:
Muting sensor does not detect
an object, AND
Light curtain beam is inter-
rupted.
Light curtain beams are not interrupted, AND
Muting sensor beams are not interrupted, AND
Muting lamp is connected, AND
Emergency stop switches are unlatched
Logic
(light curtain beam interrupted by other than work object)
Muting Sensor
Muting Sensor
Light Curtain
Light Curtain
4
(PNP type)
(PNP type)
(PNP type)
(PNP type)
Stop Switch
Emergency
Muting Function Improves Productivity
During Operation (normal operation)
Work
Object
Light Curtains
Solid State with Muting
Muting function logic for apparatus with openings
System Stop
Hazardous Area
Muting Lamp
Hazardous Area
Muting Sensors
Light curtain beams blocked
emergency stop switches and interlock switches can be used at the same time.
Make sure that the
intersection of optical
axes are in within the
hazardous area.
Safety contactor/
Safety relay ON
Muting lamp OFF
System runs
Light curtain beams blocked
Note 2: Use muting sensor with 3-wire PNP output.
Beams
blocked!
When muting is activated, the system continues operating even when:
The system stops when:
Light curtain beam is interrupted
Emergency stop switch is pressed.
Beams
blocked!
During Operation (muting)
Muting
Lamp
Hazardous Area
Light Curtain blocked
Muting sensor beam blocked
Light curtain beams blocked
Safety contactor/
Safety relay ON
Safety contactor/
Safety relay OFF
System runs
Muting lamp OFF
System stops
Muting lamp ON
(09/01/07)