FS1A-C01S IDEC, FS1A-C01S Datasheet - Page 7

Safety Controller

FS1A-C01S

Manufacturer Part Number
FS1A-C01S
Description
Safety Controller
Manufacturer
IDEC
Datasheet

Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
(09/01/07)
Logic 1 is used for safeguarding measures of machine tools and robots. It can be used with dual direct-opening components
such as emergency stop switches and interlock switches. In this logic, when a safety component is operated, the SafetyOne
shuts down the safety output immediately.
All logics have 0.5-sec input monitor error time on the dual chan-
nel direct opening inputs. For details, see user’s manual.
Note: Use spring-lock type interlock switch with solenoid. Solenoid lock type cannot be used.
The system is equipped with emergency
stop switches and interlock switches.
The system can operate when:
Input monitor error detection function
Interlock Switch
with Solenoid
(spring lock type)
The emergency stop switch is un-
latched, AND
Guard door is closed
(interlock switch contacts are closed)
Logic
Interlock Switch
Machine tool
1
Emergency
Stop Switch
General-purpose logic for various apparatus
Direct Opening
During Operation
Solenoid output OFF
Guard door locked
Safety Contactor/
Safety Relay ON
System runs
The system stops when:
The energized solenoid unlocks the
guard door.
(muting lamp output function)
The SafetyOne has a solenoid control output. When operating on
Logic 4, solenoid control output functions as a muting lamp output.
For details, see user’s manual.
Emergency stop switch is pressed,
OR
Guard door is open (interlock switch
contacts are open)
Solenoid output
Open!
Press!
Robot
OR
FS1A Safety Controller
System Stop (safe)
Solenoid output ON
function
Guard unlocked
Safety contactor/
Safety relay OFF
System stops
7