FS1A-C01S IDEC, FS1A-C01S Datasheet - Page 23

Safety Controller

FS1A-C01S

Manufacturer Part Number
FS1A-C01S
Description
Safety Controller
Manufacturer
IDEC
Datasheet

Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
(09/01/07)
When using manual start input X16
Safety Output Monitor
Logic 1 Time Chart
Note: When the iput time difference at the dual channel safety inputs is 0.5s or
Manual Start Input
(Y0, Y1, Y2, Y3)
Solenoid Output
Monitor Output
for X0, X1 (Y4)
Safety Output
RUN Monitor
more, the input monitor error is detected.
Safety Input
Safety Input
(Y12, Y13)
(Y17, Y20)
(Y16)
(X16)
(X0)
(X1)
Power ON
Initializing
(Note)
6s maximum
Safety Output ON
(Note)
0.1s maximum
0.1s minimum
Off-delay
Time
When using control start input X17
Safety Output Monitor
Manual Start Input
(Y0, Y1, Y2, Y3)
Solenoid Output
Monitor Output
for X0, X1 (Y4)
Safety Output
RUN Monitor
Safety Input
Safety Input
(Y12, Y13)
(Y17, Y20)
(Y16)
(X17)
(X0)
(X1)
(Safety inputs X2 to X13 are ON in this chart)
Power ON
FS1A Safety Controller
Initializing
(Note)
6s maximum
Safety Output ON
(Note)
0.1s minimum
0.1s maximum
Off-delay
Time
23