Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Logic 2 is used for semiconductor manufacturing systems or food packaging systems which have non-contact interlock
switches of NO/NC contacts. In this logic, components with dual NO/NC contacts such as a non-contact interlock switch
and a mechanical interlock switch, as well as dual direct-opening components such as emergency stop switch and interlock
switches can be used at the same time. When a safety component is operated, the SafetyOne shuts down the safety output
Semiconductor Manufacturing
System
In addition to safe solid state output, the SafetyOne is
equipped with a monitor output which sends internal error
information. For details, see user’s manual.
Note 1: Use spring-lock type interlock switch with solenoid. Solenoid-lock type cannot be used.
Note 2: For details about non-contact interlock switches, see user’s manual.
8
The system is equipped with non-contact
interlock switches, emergency stop
switches, and an interlock switch.
The system can operate when:
Monitor output function
Emergency stop switch is unlatched,
AND
Guard doors are closed
Logic
Non-contact
Interlock Switches
(1NC+1NO)
Emergency
Stop Switch
Interlock Switch
with Solenoid
(spring lock type)
2
General-purpose logic for NO/NC contact inputs
Normally Open and Normally Closed
During Operation
Solenoid output OFF
Guard locked
Safety contactor/
Safety relay ON
System runs
Food Packaging System
The system stops when:
Each logic has the option of setting one of two start inputs.
Choose one that conforms to the system risk assessment.
Emergency stop switch is pressed,
OR
Guard door is open
Auto manual start to detect input level
Control start to detect the input's ON to OFF transition and
the time
OR
Auto manual start and control start
Open!
Interlock Switch
with Solenoid
Press!
Press
System Stop (safe)
Solenoid output ON
Guard unlocked
Safety contactor/
Safety relay OFF
System stops
(09/01/07)