Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
(09/01/07)
Wiring
For wiring the SafetyOne, spring clamp (supplied with the Safety-
One) or crimp connector can be used. For crimp type connector,
contact Tyco Electronics AMP.
Push the connector into the SafetyOne until the latches click. For
removal, make sure to press down the latches completely before
removing the connector, otherwise the connector and wires may be
damaged.
Applicable Wire and Ferrule Size
(spring clamp type)
AWG#18 to 24 (recommended wire: UL1007)
Strip length 7.0 ±0.3mm.
When using a ferrule for wiring, select a ferrule which satisfies the
terminal specifications shown below.
Wiring to Spring Clamp Connector
When wiring to a connector, make sure that the connector is
removed from the SafetyOne, otherwise the connector and the
SafetyOne may be damaged. For wiring, use the connecting tool
FS9Z-SD01. When rewiring, use the wire of the same type and
size.
1.
2.
3.
4.
5.
6.
7.
8.
9.
Do not disassemble, repair, or modify the SafetyOne, otherwise
the safety characteristics of the SafetyOne are impaired. Turn off
the power to the SafetyOne before installation, removing, wiring,
maintenance, or inspection of the SafetyOne. Failure to do so
may cause electrical shocks or fire hazard.
Before operating the SafetyOne, read the instruction sheet and
the user’s manual carefully, and ensure that the environment
conforms to the requirements of the SafetyOne specifications.
If the SafetyOne is operated in an environment that exceeds the
specifications of the SafetyOne, the safety characteristics of the
SafetyOne are impaired.
The installation, wiring, configuration, and operation of the Safe-
tyOne must be performed by safety experts only. Safety experts
are personnel who have necessary qualifications authorizing
them to perform designing, installation, operation, maintenance,
and disposal of the SafetyOne. Persons without technical exper-
tise must not use the SafetyOne.
The SafetyOne must be subjected to a regular test which proves
that all functions of the SafetyOne satisfy the required standard.
Perform daily operation check on the SafetyOne.
Install the SafetyOne according to the instruction sheet and the
user’s manual. Improper installation may cause failure of the
SafetyOne.
Do not use the monitor outputs or solenoid/lamp outputs as safe-
ty outputs, otherwise the system safety is impaired in case the
SafetyOne or connected components fail.
Do not use the start input and the external device monitor input
as safety inputs, otherwise the system safety is impaired in case
the SafetyOne or connected components fail.
Use the SafetyOne in compliance with laws and regulations of
the country or region where the SafetyOne is used.
Safety Precautions
a
a: 1.02 to 1.21 mm
b: 0.95 to 1.21 mm
Applicable wire: AWG#24 (recommended: UL1007)
Ferrule
Terminal
Wire
1. Insert the connecting tool completely into the tool slot in the
2. Insert a wire into the wire slot. When using a stranded wire, twist
3. While the wire is inserted, remove the connecting tool. Wiring is
4. To remove the wire, press down the spring using the connecting
When using a screwdriver for wiring, use a screwdriver of 2.4mm
wide maximum at the tip. Pay extra attention when using a screw-
driver, so that the connector is not damaged.
1. Insert the screwdriver into the tool slot on the connector at an
2. While the screwdriver is inserted, insert a wire into the wire slot.
3. While the wire is inserted remove the screwdriver. Wiring is
4. To remove the wire, press down the spring using the screwdriver
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
Wiring Using the Connecting Tool
Using a Screwdriver
connector at an angle.
the wire beforehand so that the wire does not become loose.
completed. Pull the wire lightly to confirm whether it is clamped
securely.
tool and pull out the wire.
angle, and press down so as to pry open the spring. Do not
apply excessive force when inserting the screwdriver, otherwise
the connector will be damaged. Do not insert the screwdriver
into the wire slot.
When using a stranded wire, twist the wire beforehand so that
the wire does not become loose.
completed. Pull the wire lightly to confirm whether it is clamped
securely.
and pull out the wire.
Use safety inputs and safety outputs in circuit configurations
which conform to safety requirements and applications.
Calculate the respective safety distances, while taking into con-
sideration the response time of the SafetyOne and safety com-
ponents connected to the SafetyOne.
Separate the SafetyOne from components and wires which do
not satisfy Class 2 circuit requirements.
Safety performance differs depending on system configurations.
Use a power supply that meets the following required specifica-
tions completely:
- Complies with the power supply rating of the SafetyOne.
- The primary and secondary circuits are separated by double
- Has the functionality equivalent of the control voltage and cur-
- Complies with safety laws or regulations relating to electrical
Ground the V– line (0V DC) for ground diagnosis.
After setting a new configuration or modifying a configuration,
check each input and output function.
Implement protective measure so that personal other than safety
responsible persons operating the SafetyOne do not modify the
configuration.
The SafetyOne is designed for installation within an enclosure.
Do not install the SafetyOne outside an enclosure. Install the
SafetyOne in enclosure of IP54 or higher protection.
Install the SafetyOne in environments specified in the catalog,
instruction sheet, and user’s manual. If the SafetyOne is used in
places where the SafetyOne is subjected to high temperature,
high humidity, condensation, corrosive gases, excessive vibra-
insulation or reinforced insulation.
rent of Class 2 circuit specified by UL508 or UL1310.
safety or EMC of the country where the SafetyOne is used.