FS1A-C01S IDEC, FS1A-C01S Datasheet - Page 14

Safety Controller

FS1A-C01S

Manufacturer Part Number
FS1A-C01S
Description
Safety Controller
Manufacturer
IDEC
Datasheet

Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Logic 7 is used for partial stop of systems such as machine tools, semiconductor manufacturing equipment, and food pack-
aging machines. Four safety outputs can be controlled in two lines.
Two-line outputs can be controlled separately for partial stop, improving production efficiency greatly compared to entire
stop.
Note: Use spring-lock type interlock switch with solenoid. Solenoid-lock type cannot be used.
14
The system is equipped with an emergency stop switch and interlock
switches. The system is configured so that pressing the emergency
stop switch shuts down the entire system, while opening a door
(equipped with an interlock switch) shuts down only the corresponding
partial system. The other partial system keeps operating.
The entire system can operate when:
The emergency stop switch is unlatched, AND
The guards are closed (interlock switch contacts are closed)
Logic
Interlock Switch A
7
Partial Stop Improves Productivity
Hazardous Area A
Emergency Stop
Switch
Partial stop 1 logic for various apparatus
Partial Stop 1
During Operation
Hazardous Area B
Interlock Switch B
Interlock Switch A
Interlock Switch A
Interlock Switch B
Interlock Switch B
(spring lock type)
(spring lock type)
Emergency Stop
with Solenoid
with Solenoid
Switch
Solenoid output A OFF
Solenoid output B OFF
Guard locked
Guard locked
Safety contactor/
Safety relay
Safety output A ON
System runs
Safety output B ON
System runs
(09/01/07)

Related parts for FS1A-C01S