FS1A-C01S IDEC, FS1A-C01S Datasheet - Page 38

Safety Controller

FS1A-C01S

Manufacturer Part Number
FS1A-C01S
Description
Safety Controller
Manufacturer
IDEC
Datasheet

Specifications of FS1A-C01S

No. Of Analog Outputs
11
No. Of Digital Inputs
30
Supply Voltage Dc, Min
20.4V
External Width
72mm
Supply Voltage Max
28.8VDC
External Depth
113.5mm
Supply Voltage Dc, Max
28.8V
Mounting Type
DIN Rail
Rohs Compliant
Yes
Approval Bodies
CULus, CE, TUV
External Height
114.5mm
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Teach Mode
38
Manual Start Input
Mode Select Input
Mode Select Input
Monitor Output for
Control Start Input
Safety Input (X2)
Safety Input (X3)
Note 1: The detection time of input monitor error is infinite at dual channel dependent inputs (X2-X3).
Note 2: The above chart shows an example when the control start input (X17) is turned on before turning
(Y0, Y1, Y2, Y3)
Solenoid Output
Logic 6 Time Chart
X10, X11 (Y10)
Monitor Output
for X0, X1 (Y4)
Monitor Output
for X2, X3 (Y5)
Safety Output
Safety Output
RUN Monitor
Safety Input
(Y12, Y13)
(Y17, Y20)
(X10, X11)
When the input time difference at the dual channel direct opening inputs (X4-X5, X6-X7, X10-X11,
and X12-13) is 0.5s or more, input monitor error is detected.
on the manual start input (X16).
Monitor
(Y16)
(X16)
(X17)
(X0)
(X1)
Power ON
Initializing
(Note 1)
(Note 2)
6s max.
Safety Output
ON
0.1s to 5s
(Note 1)
0.1s min.
0.1s max.
(Safety inputs X4 to X7, X12, and X13 are on in this chart.)
Off-delay
Time
FS1A Safety Controller
Safety Output
ON
0.1s min.
0.1s max.
Off-delay
Time
0.1s
max.
Safety Output
ON
Safety Output Monitor
Auto Mode
Control Start Input
Mode Select Input
Mode Select Input
Monitor Output for
(Y0, Y1, Y2, Y3)
Solenoid Output
Monitor Output
for X0, X1 (Y4)
Safety Output
RUN Monitor
Note: When the input time difference is 0.5s or more,
Safety Input
Safety Input
Safety Input
X4, X5 (Y6)
(Y12, Y13)
(Y17, Y20)
(X2, X3)
(Y16)
input monitor error is detected.
(X17)
(X0)
(X1)
(X4)
(X5)
Power ON
(Safety inputs X6 to X13 are on in this chart.)
Initializing
(Note)
6s max.
Safety Output
ON
(Note)
0.1s to 5s
0.1s max.
Off-delay
Time
(09/01/07)