EP4CGX75DF27C7N Altera, EP4CGX75DF27C7N Datasheet - Page 104

no-image

EP4CGX75DF27C7N

Manufacturer Part Number
EP4CGX75DF27C7N
Description
Cyclone IV GX
Manufacturer
Altera
Series
CYCLONE® IV GXr

Specifications of EP4CGX75DF27C7N

Number Of Logic Elements/cells
73920
Number Of Labs/clbs
4620
Total Ram Bits
4257792
Number Of I /o
310
Number Of Gates
-
Voltage - Supply
1.16 V ~ 1.24 V
Mounting Type
*
Operating Temperature
0°C ~ 85°C
Package / Case
*
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
EP4CGX75DF27C7N
Manufacturer:
SONGCHUAN
Quantity:
1 000
Part Number:
EP4CGX75DF27C7N
Manufacturer:
Altera
Quantity:
10 000
Part Number:
EP4CGX75DF27C7N
Manufacturer:
ALTERA
0
5–42
Cyclone IV Device Handbook, Volume 1
f
To perform one dynamic phase shift step, follow these steps:
1. Set phaseupdown and phasecounterselect as required.
2. Assert phasestep for at least two scanclk cycles. Each phasestep pulse
3. De-assert phasestep.
4. Wait for phasedone to go high.
5. You can repeat steps
All signals are synchronous to scanclk, so they are latched on the scanclk edges
and must meet t
Figure 5–26. PLL Dynamic Phase Shift
Dynamic phase shifting can be repeated indefinitely. All signals are synchronous to
scanclk, so they must meet t
The phasestep signal is latched on the negative edge of scanclk. In
this is shown by the second scanclk falling edge. phasestep must stay high for at
least two scanclk cycles. On the second scanclk rising edge after phasestep is
latched (indicated by the fourth rising edge), the values of phaseupdown and
phasecounterselect are latched and the PLL starts dynamic phase shifting for the
specified counter or counters and in the indicated direction. On the fourth scanclk
rising edge, phasedone goes high to low and remains low until the PLL finishes
dynamic phase shifting. You can perform another dynamic phase shift after the
phasedone signal goes from low to high.
Depending on the VCO and scanclk frequencies, thephasedone low time may be
greater than or less than one scanclk cycle.
After phasedone goes from low to high, you can perform another dynamic phase
shift. phasestep pulses must be at least one scanclk cycle apart.
For information about the ALTPLL_RECONFIG MegaWizard Plug-In Manager,
refer to the
enables one phase shift.
shifts.
phasecounterselect
ALTPLL_RECONFIG Megafunction User
phaseupdown
SU
phasestep
phasedone
or t
scanclk
H
requirements (with respect to the scanclk edges).
1
through
SU
or t
4
H
as many times as required to get multiple phase
requirements (with respect to scanclk edges).
Chapter 5: Clock Networks and PLLs in Cyclone IV Devices
Guide.
© December 2010 Altera Corporation
Figure
PLL Reconfiguration
5–26,

Related parts for EP4CGX75DF27C7N