LAN9312-NZW SMSC, LAN9312-NZW Datasheet - Page 45

Ethernet ICs Hi Per 2 Port 10/100 Ethernet Switch

LAN9312-NZW

Manufacturer Part Number
LAN9312-NZW
Description
Ethernet ICs Hi Per 2 Port 10/100 Ethernet Switch
Manufacturer
SMSC
Type
Two Port Managed Ethernet Switchr
Datasheet

Specifications of LAN9312-NZW

Ethernet Connection Type
10 Base-T, 100 Base-TX
Minimum Operating Temperature
0 C
Mounting Style
SMD/SMT
Product
Ethernet Switches
Number Of Transceivers
1
Standard Supported
802.3, 802.3u
Data Rate
10 Mbps, 100 Mbps
Supply Voltage (max)
3.3 V
Supply Voltage (min)
0 V
Supply Current (max)
186 mA, 295 mA
Maximum Operating Temperature
+ 70 C
Package / Case
TQFP-100
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LAN9312-NZW
Manufacturer:
Standard
Quantity:
143
Part Number:
LAN9312-NZW
Manufacturer:
Microchip Technology
Quantity:
10 000
High Performance Two Port 10/100 Managed Ethernet Switch with 32-Bit Non-PCI CPU Interface
Datasheet
SMSC LAN9312
4.2.4.2
STRAP NAME
manual_FC_strap_2
BP_EN_strap_mii
FD_FC_strap_mii
manual_FC_strap_mii
SQE_test_disable_strap_mii
Hard-Straps
Hard-straps are latched upon Power-On Reset (POR) or pin reset (nRST) only. Unlike soft-straps,
hard-straps always have an associated pin and cannot be overridden by the EEPROM Loader. These
straps are used as either direct configuration values or as register defaults.
all hard-straps and their associated pin. These straps, along with their pin assignments are also fully
defined in
Table 4.2 Soft-Strap Configuration Strap Definitions (continued)
Chapter 3, "Pin Description and Configuration," on page
DESCRIPTION
Port 2 Manual Flow Control Enable Strap: Configures the
default value of the
Select (MANUAL_FC_2)
Control Register
flow control is determined by auto-negotiation (if enabled),
and symmetric PAUSE is advertised (bit 10 of the
PHY Auto-Negotiation Advertisement Register
(PHY_AN_ADV_x)
When configured high, flow control is determined by the
Port 2 Full-Duplex Transmit Flow Control Enable
(TX_FC_2)
Enable (RX_FC_2)
advertised (bit 10 of the
Advertisement Register (PHY_AN_ADV_x)
Port 0(Host MAC) Backpressure Enable Strap:
Configures the default value for the
Enable (BP_EN_MII)
Flow Control Register
configured low, backpressure is disabled. When configured
high, backpressure is enabled.
Port 0(Host MAC) Full-Duplex Flow Control Enable
Strap: Configures the default of the TX_FC_MII and
RX_FC_MII bits in the
Control Register (MANUAL_FC_MII)
manual full-duplex flow control is selected. When
configured low, flow control is disabled on RX/TX. When
configured high, flow control is enabled on RX/TX.
Port 0(Host MAC) Manual Flow Control Enable Strap:
Configures the default value of the MANUAL_FC_MII bit in
the
(MANUAL_FC_MII). When configured low, flow control is
determined by Virtual Auto-Negotiation (if enabled). When
configured high, flow control is determined by TX_FC_MII
and RX_FC_MII bits in the
Control Register
SQE Heartbeat Disable Strap: Configures the Signal
Quality Error (Heartbeat) test function by controlling the
default value of the SQEOFF (bit 0) of the
Special Control/Status Register
(VPHY_SPECIAL_CONTROL_STATUS). When configured
low, SQEOFF defaults to 0 and SQE test is enabled. When
configured high, SQEOFF defaults to 1 and SQE test is
disabled.
Port 0(Host MAC) Manual Flow Control Register
and
DATASHEET
Port 2 Full-Duplex Receive Flow Control
(MANUAL_FC_2). When configured low,
(MANUAL_FC_MII).
is set).
Port 2 Full-Duplex Manual Flow Control
bits, and symmetric PAUSE is not
bit of the
(MANUAL_FC_MII). When
Port 0(Host MAC) Manual Flow
45
Port x PHY Auto-Negotiation
bit in the
Port 0(Host MAC) Manual Flow
Port 0(Host MAC) Manual
Port 2 Manual Flow
Port 0 Backpressure
which are used when
is cleared).
Virtual PHY
26.
Port x
Table 4.3
PIN / DEFAULT
VALUE
0b
1b
1b
0b
0b
Revision 1.7 (06-29-10)
provides a list of