TXC-06312BIOG Transwitch Corporation, TXC-06312BIOG Datasheet - Page 69

no-image

TXC-06312BIOG

Manufacturer Part Number
TXC-06312BIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-06312BIOG

Lead Free Status / Rohs Status
Supplier Unconfirmed
6 9 o f 2 0 2
Symbol
a. Only applies if a write access is preceded by a read access.
b. CS may stay low between 2 successive accesses to the same peripheral.
c. Only applies if a write access is followed by a read access.
d. No timing constraint between the rising edges of CS and WR are defined. CS is only latched
e. Between accesses to different peripherals.
t
H3
t
t
t
t
t
SU2
SU3
t
D10
SU1
SU4
t
t
t
t
t
t
t
t
t
H2
at the beginning of an access.
t
t
H1
H4
D1
D2
D3
D4
D5
D6
D7
t
H
L
b, d
c
e
a
b
20 ns
0.4t
0.4t
-0.9t
0 ns
0 ns
-0.9t
0 ns
t
-
0 ns
0 ns
0 ns
0 ns
4 ns
-
t
TBD
t
Min
-
-
-
-
-
-
-
-
-
-
-
20 ns
8 ns
7 ns
-
20 ns
-
TBD
-
Max
- Timing Characteristics -
CLK clock period
CLK clock low phase pulse width
CLK clock high phase pulse width
Setup time of A to falling edge WR
Setup time of RD to falling edge WR
Setup time of CS to falling edge WR
Setup time of D to falling edge WR
Hold time of A to active edge RDY
Hold time of RD to rising edge WR
Hold time of CS to rising edge WR
Hold time of D to active edge RDY
Delay from falling edge WR to RDY driving
Delay from falling edge CLK to active edge RDY
Delay from rising edge WR to inactive edge RDY
Delay from RDY going inactive to RDY going in tristate
Delay from rising edge WR to RDY going in tristate
WR inactive pulse width
Response latency
CS inactive pulse width
Description
PRELIMINARY TXC-06312B-MB, Ed. 2
PHAST-12N Device
DATA SHEET
TXC-06312B
June 2005