TMPM382FSFG Toshiba, TMPM382FSFG Datasheet - Page 479

no-image

TMPM382FSFG

Manufacturer Part Number
TMPM382FSFG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM382FSFG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
64K
Rom Type
Flash
Ram (kbytes)
8K
Number Of Pins
64
Package
QFP(14x14)
Vcc
5V
Cpu Mhz
40
Ssp (ch) Spi
1
I2c/sio (ch)
1
Uart/sio (ch)
3
Usb
-
Can
-
Ethernet
-
External Bus Interface
N
Cs/wait Controller (ch)
-
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
-
12-bit Ad Converter
10
16-bit Timer / Counter
6
Motor / Igbt Control
Y
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
Y
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
Y
Hardware Cec Controller
-
Comparators
-
Low-voltage Detector
Y
Etm Hardware Trace
2-bit
16.2.9 Remote Control Receive Control Register 3 [RMCRCR3]
<RMCDATH6:0>:
<RMCDATL6:0>:
(Note)
Read/Write
Read/Write
bit Symbol
After reset
bit Symbol
After reset
Function
Function
If the <RMCPHM> bit of the Remote Control Receive Control Register 2 is “0”,
<RMCDATH6:0> are not enabled. The bits are enabled when <RMCPHM> is ”1”.
Specifies a larger threshold (within a range of 1.5T and 2T) to determine a pattern
of remote control signal in a phase method. If the measured cycle exceeds the
threshold, the bit is determined as “10”. If not, the bit is determined as “01”.
Calculating formula of the threshold: RMCDATHx1/fs[s].
Specifies two kinds of thresholds: a threshold to determine whether a data bit is 0
or 1; a smaller threshold (within a range of 1T and 1.5T) to determine a pattern of
remote control signal in a phase method.
As for the determination of data bit, if the measured cycle exceeds the threshold,
the bit is determined as “1”. If not, the bit is determined as “0”. Calculating formula
of the threshold: RMCDATL×1/fs[s].
As for the determination of a remote control signal pattern in a phase method, if the
measured cycle exceeds the threshold, the bit is determined as “01”. If not, the bit
is determined as “00”. Calculating formula of the threshold to determine 0 or 1:
RMCDATLx1/fs[s].
”0” is
read.
”0” is
read.
15
R
7
R
0
0
Larger threshold to determine a signal pattern in a phase method
RMCDATH×1/fs[s]
Threshold to determine 0 or 1
smaller threshold to determine a signal pattern in a phase method
RMCDATL×1/fs[s]
TMPM380/M382 - 9 / 25 -
RMCDAT
RMCDAT
14
H6
L6
6
RMCDAT
RMCDAT
13
H5
L5
5
RMCDAT
RMCDAT
12
H4
L4
4
RMCDAT
RMCDAT
R/W
R/W
11
H3
L3
3
0
0
RMCDAT
RMCDAT
10
H2
L2
2
RMCDAT
RMCDAT
TMPM380/M382
H1
L1
9
1
RMCDAT
RMCDAT
H0
L0
8
0

Related parts for TMPM382FSFG