TMPM382FSFG Toshiba, TMPM382FSFG Datasheet - Page 65

no-image

TMPM382FSFG

Manufacturer Part Number
TMPM382FSFG
Description
Manufacturer
Toshiba
Datasheet

Specifications of TMPM382FSFG

Product Summaries
Summary
Lead Free
Yes
Rohs Compatible Product(s)
Available
Rom (kbytes)
64K
Rom Type
Flash
Ram (kbytes)
8K
Number Of Pins
64
Package
QFP(14x14)
Vcc
5V
Cpu Mhz
40
Ssp (ch) Spi
1
I2c/sio (ch)
1
Uart/sio (ch)
3
Usb
-
Can
-
Ethernet
-
External Bus Interface
N
Cs/wait Controller (ch)
-
Dma Controller
2
10-bit Da Converter
-
10-bit Ad Converter
-
12-bit Ad Converter
10
16-bit Timer / Counter
6
Motor / Igbt Control
Y
Real Time Clock
1
Watchdog Timer
Y
Osc Freq Detect
Y
Clock Gear
Y
Low-power Hold Function
-
Remote Control Interface
Y
Hardware Cec Controller
-
Comparators
-
Low-voltage Detector
Y
Etm Hardware Trace
2-bit
7 Exceptions
7.4
The count clock frequency varies with each product, and so the value set in the SysTick Calibration Value
Register also varies with each product.
SysTick Control and Status Register, the counter loads with the value set in the Reload Value Register
and begins counting down. When the counter reaches “0”, a SysTick exception occurs. It is also
possible to pend exceptions and use a flag to know when the timer reaches “0”.
(Note)
SysTick provides interrupt features using the CPU’s system timer.
In case set a value in the SysTick Reload Value Register and enable the SysTick features in the
The SysTick Calibration Value Register holds a reload value for counting 10 ms with the system timer.
SysTick
In this product, the system timer counts based on a clock obtained by dividing the
clock input from the X1 pin by 32.
The SysTick Calibration Value Register is set to 0x9C4, which provides 10 ms timing
when the clock input from X1 is 8 MHz. In case of 10MHz clock input, 10 ms timing is
made by setting 0xC35 to SysTick Reload Register.
TMPM380/M382 - 10 / 59 -
TMPM380/M382

Related parts for TMPM382FSFG