31.2.3.3
32059J–12/2010
Power Manager
3. SPI Glitch on RXREADY flag in slave mode when enabling the SPI or during the first
4. SPI CSNAAT bit 2 in register CSR0...CSR3 is not available
5. SPI disable does not work in SLAVE mode
6. SPI Bad Serial Clock Generation on 2nd chip_select when SCBR = 1, CPOL=1 and
1. PLL Lock control does not work
2. Wrong reset causes when BOD is activated
3. System Timer mask (Bit 16) of the PM CPUMASK register is not available
Fix/Workaround
When multiple CS are in use, if one of the baudrate equals to 1, the other must also equal 1
if CPOL=1 and CPHA=0.
transfer
In slave mode, the SPI can generate a false RXREADY signal during enabling of the SPI or
during the first transfer.
Fix/Workaround
1. Set slave mode, set required CPOL/CPHA.
2. Enable SPI.
3. Set the polarity CPOL of the line in the opposite value of the required one.
4. Set the polarity CPOL to the required one.
5. Read the RXHOLDING register.
Transfers can now befin and RXREADY will now behave as expected.
SPI CSNAAT bit 2 in register CSR0...CSR3 is not available.
Fix/Workaround
Do not use this bit.
SPI disable does not work in SLAVE mode.
Fix/Workaround
Read the last received data, then perform a Software Reset.
NCPHA=0
When multiple CS are in use, if one of the baudrate equals to 1 and one of the others doesn't
equal to 1, and CPOL=1 and CPHA=0, then an aditional pulse will be generated on SCK.
Fix/workaround
When multiple CS are in use, if one of the baudrate equals 1, the other must also equal 1 if
CPOL=1 and CPHA=0.
PLL lock Control does not work.
Fix/Workaround
In PLL Control register, the bit 7 should be set in order to prevent unexpected behaviour.
Setting the BOD enable fuse will cause the Reset Cause Register to list BOD reset as the
reset source even though the part was reset by another source.
Fix/Workaround
Do not set the BOD enable fuse, but activate the BOD as soon as your program starts.
System Timer mask (Bit 16) of the PM CPUMASK register is not available.
Fix/Workaround
Do not use this bit.
AT32UC3B
665
Related parts for at32uc3b0512-z2ues
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
INTERVAL AND WIPE/WASH WIPER CONTROL IC WITH DELAY
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
Low-Voltage Voice-Switched IC for Hands-Free Operation
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
MONOLITHIC INTEGRATED FEATUREPHONE CIRCUIT
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
AM-FM Receiver IC U4255BM-M
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
Monolithic Integrated Feature Phone Circuit
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
Multistandard Video-IF and Quasi Parallel Sound Processing
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
High-performance EE PLD
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
8-bit Flash Microcontroller
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
2-Wire Serial EEPROM
Manufacturer:
ATMEL Corporation
Datasheet:
Part Number:
Description:
U6046BREAR WINDOW HEATING TIMER / LONG-TERM TIMER
Manufacturer:
ATMEL Corporation
Datasheet: