cx29600 Mindspeed Technologies, cx29600 Datasheet - Page 153

no-image

cx29600

Manufacturer Part Number
cx29600
Description
Optiphytm - M155 Sts-3 Sonet/sdh Multiplexer
Manufacturer
Mindspeed Technologies
Datasheet
CX29600
CX29600 Data Sheet
RXK2 (Receive K2 Line Overhead Status Register)
The RXK2 register contains the received K2 Line Overhead byte. The K1 byte and bits 0–5 of the K2 byte are
allocated for APS signaling between line level entities. Bits 6-8 of the K2 byte indicate bidirectional or
unidirectional APS. Bits 6-8 are also used to indicate Line AIS and RDI conditions. These bytes are defined
only for the first STS-1 of the STS-3.
RXK3 (Receive Z4/K3 Path Overhead Status Register)
The RXK3 register contains the received Z4/K3 Path Overhead byte.
29600-DSH-001-B
7-0
7-0
Bit
Bit
Default
Default
00h
xx
hex address: 0x02F
hex address:
RxK2[1:8]
RxK3[1:8]
Mindspeed Technologies
Name
Name
Receive value for the K2 Line Overhead byte.
Receive value for the Z4/K3 Path Overhead byte.
Path 1
Path 2
Path 3
Path 4
0x0DB
0x09B
0x11B
0x15B
Description
Description
4.1 Memory Map
4.0 Registers
4-47

Related parts for cx29600