4.0 Registers
4.1 Memory Map
RXLIN (Receive Line Overhead Status Register)
The RXLIN register contains status information for the receive Line Overhead.
RXN1 (Receive Z5/N1 Path Overhead Status Register)
The RXN1 register holds the received Z5/N1 Path Overhead byte.
4-48
NOTE(S):
(1)
(2)
This status shows an event that has occurred since the register was last read.
This status reflects the current state of the circuit.
7-0
Bit
Bit
7
6
5
4
3
2
1
0
Default
Default
xx
0
0
x
x
x
x
x
x
hex address: 0x045
hex address:
S1_Unstable
RxN1[1:8]
Mindspeed Technologies
PrbsErr
RDI-L
AIS-L
B2Err
REI-L
Name
Name
1
1
2
2
2
Reserved, set to zero.
This bit indicates that an AIS-L condition exists.
This bit indicates that an RDI-L condition exists.
This bit indicates that a Line BIP Error was received.
This bit indicates that an REI-L condition was received.
Reserved, set to zero.
This bit indicates that an S1 Unstable condition exists.
This bit indicates that a PRBS error was received.
Receive value for the Z5/N1 Path Overhead byte.
Path 1
Path 2
Path 3
Path 4
0x0DC
0x09C
0x11C
0x15C
Description
Description
CX29600 Data Sheet
29600-DSH-001-B
CX29600

Related parts for cx29600