Framer Register Architecture
The following registers are dedicated to the exchange termination and its remote end interface. The alarm condi-
tions to trigger errored seconds and severely errored seconds are defined in Table 32 and the ET and ET-RE
enable registers, FRM_PR14 and FRM_PR15. The thresholds are defined in registers FRM_PR11—FRM_PR13.
Table 74. Exchange Termination and Exchange Termination Remote End Interface Status
Bit
0
1
2
3
4
5
6
7
Register (FRM_SR5) (Y05)
ETREBES
ETRESES
ETREUAS
ETREES
Symbol
ETBES
ETSES
ETUAS
ETES
ET Errored Second. A 1 indicates the receive framer detected an errored second at the
exchange termination (ET).
ET Bursty Errored Second. A 1 indicates the receive framer detected a bursty errored
second at the ET.
ET Severely Errored Second. A 1 indicates the receive framer detected a severely
errored second at the ET.
ET Unavailable State. A 1 indicates the receive framer has detected at least ten con-
secutive severely errored seconds. Upon detecting ten consecutive nonseverely errored
seconds, the receive framer will clear this bit. ITU Recommendation G.826 is used
resulting in a ten-second delay in the reporting of this condition.
ET-RE Errored Second. A 1 indicates the receive framer detected an errored second at
the exchange termination remote end (ET-RE).
ET-RE Bursty Errored Second. A 1 indicates the receive framer detected a bursty
errored second at the ET-RE.
ET-RE Severely Errored Second. A 1 indicates the receive framer detected a severely
errored second at the ET-RE.
ET-RE Unavailable State. A 1 indicates the receive framer has detected at least ten
consecutive severely errored seconds. Upon detecting ten consecutive nonseverely
errored seconds, the receive framer will clear this bit. ITU Recommendation G.826 is
used resulting in a ten-second delay in the reporting of this condition.
(continued)
Description
TFRA08C13 OCTAL T1/E1 Framer
133
Related parts for TFRA08C13-DB
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
Power Modules DC/DC Converters
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
Quad differential driver. Intern. term. none. Surge-protection no.
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
InGaAs Avalanche Photodetector
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
Ringing Access Switch
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
Quad differential receiver
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
ORCA feild-programmable gate array. Voltage 3.3 V.
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
Quad differential driver. Intern. term. none. Surge-protection no.
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
Quad Differential Line Receivers
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
4096-channel, 32-highway time-slot interchager
Manufacturer:
Agere Systems
Datasheet:
Part Number:
Description:
QUAD-FET (Fast Ethernet Transceiver) for 10Base-T/100Base-TX/FX
Manufacturer:
Agere Systems
Datasheet: