Event Counters Definition
The error events monitored in the receive framer’s status registers are defined in Table 32 for the hardwired
(default) threshold values. The errored second and severely errored second threshold registers can be pro-
grammed through FRM_PR11—FRM_PR13 such that the errored and severely errored second counters function
as required by system needs. DS1 errors are reported in the ET Error registers, FRM_SR20 through FRM_SR35.
For the framer to correctly report coding and BPV errors, the LIU/Framer interface must be configured as dual rail
mode.
Table 32. Event Counters Definition
Bipolar
Violations
(BPVs)
Frame
Alignment Errors
(FERs)
CRC Checksum
Errors
Excessive CRC
Errors
Received
E bits = 0
Errored Second
Events
Error Event
AMI
B8ZS
CEPT HDB3
SF: D4
SF: SLC -96
SF: DDS
ESF
CEPT
ESF or CEPT with CRC Any received checksum in error
ESF
CEPT with CRC
CEPT with CRC-4
All
DS1: non-ESF
DS1: ESF
CEPT without CRC-4
CEPT with CRC-4 (ET1) Any CRC-4 errors within a one second interval
CEPT with CRC-4
(ET1 remote)
CEPT with CRC-4 (NT1) Any Sa6 = 001x (binary) code event within a one
CEPT with CRC-4
(NT1 remote)
Functional Mode
Any bipolar violation or 16 or more consecutive zeros
Any BPV, code violation, or any 8-bit interval with no
one pulse
Any BPV, code violation, or any 4-bit interval with no
one pulse
Any F
F
Any F
F
Any F
Any F
Any FAS (0011011) or NOT FAS (bit 2) bit error if
register FRM_PR10, bit 2 = 0.
Any FAS (0011011) bit error if register FRM_PR10,
bit 2 = 1.
E bits = 0 in frame 13 and frame 15
Any one of the relevant error conditions enabled in
registers FRM_PR14—FRM_PR18 within a one
second interval
Any framing bit errors within a one second interval
Any CRC-6 errors within a one second interval
Any framing errors within a one second interval
Any E bit = 0 event within a one second interval
second interval
Any Sa6 = 00x1 (binary) code event within a one
second interval
T
T
320 checksum errors in a one second interval
915 checksum errors in a one second interval
bit errors (FRM_PR10 bit 2 = 0)
bit errors (FRM_PR10 bit 2 = 0)
T
T
T
E
(continued)
, F
or F
or F
bit error
S
, or time slot 24 FAS bit error
S
S
bit errors (FRM_PR10 bit 2 = 1) or any
bit errors (FRM_PR10 bit 2 = 1) or any
Definition
TFRA08C13 OCTAL T1/E1 Framer
Counter Size
NONE
(bits)
16
16
16
16
16