The receive muting function can be selected by setting RxMUTE to "1" in the appropriate global register. If
selected, any channel that experiences an RLOS condition will automatically pull RPOS and RNEG "Low" to
prevent data chattering. If RLOS does not occur, the RxMUTE will remain inactive until an RLOS on a given
channel occurs. The default setting for RxMUTE is "0" which is disabled. A simplified block diagram of the
RxMUTE function is shown in
F
2.6
IGURE
12. S
RxMUTE (Receiver LOS with Data Muting)
IMPLIFIED
B
LOCK
Figure
D
IAGRAM OF THE
RxMUTE
RLOS
12.
RPOS
RNEG
R
X
MUTE F
8-CHANNEL E1 SHORT-HAUL LINE INTERFACE UNIT