PIC18F6680-I/L Microchip Technology, PIC18F6680-I/L Datasheet - Page 299

Microcontrollers (MCU) 64KB 3328 RAM 52 I/O

PIC18F6680-I/L

Manufacturer Part Number
PIC18F6680-I/L
Description
Microcontrollers (MCU) 64KB 3328 RAM 52 I/O
Manufacturer
Microchip Technology
Datasheet

Specifications of PIC18F6680-I/L

Processor Series
PIC18F
Core
PIC
Data Bus Width
8 bit
Data Ram Size
3.25 KB
Interface Type
I2C/SPI/AUSART/CAN
Maximum Clock Frequency
40 MHz
Number Of Programmable I/os
53
Number Of Timers
5
Operating Supply Voltage
4.2 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
52715-96, 52716-328, 52717-734, 52712-325, EWPIC18
Development Tools By Supplier
PG164130, DV164035, DV244005, DV164005, PG164120, ICE2000, ICE4000, DV164136
Minimum Operating Temperature
- 40 C
On-chip Adc
12-ch x 10-bit
Program Memory Type
Flash
Program Memory Size
64 KB
Package / Case
PLCC-68
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F6680-I/L
Manufacturer:
RUBYCON
Quantity:
46 000
Part Number:
PIC18F6680-I/L
Manufacturer:
MICROCH
Quantity:
20 000
23.2.3.1
The ECAN module contains 6 message buffers that can
be programmed as transmit or receive buffers. Any of
these buffers can also be programmed to automatically
handle RTR messages.
REGISTER 23-22: BnCON: TX/RX BUFFER n CONTROL REGISTERS IN RECEIVE MODE
 2004 Microchip Technology Inc.
Note:
bit 7
bit 6
bit 5
bit 4-0
These registers are not used in Mode 0.
Programmable TX/RX and
Auto RTR Buffers
[0
bit 7
Legend:
C = Clearable bit
‘1’ = Bit is set
RXFUL: Receive Full Status bit
1 = Receive buffer contains a received message
0 = Receive buffer is open to receive a new message
RXM1: Receive Buffer Mode bit
1 = Receive all messages including partial and invalid (acceptance filters are ignored)
0 = Receive all valid messages as per acceptance filters
RTRRO: Read-Only Remote Transmission Request bit for Received Message
1 = Received message is a remote transmission request
0 = Received message is not a remote transmission request
FILHIT4:FILHIT0: Filter Hit bits
These bits indicate which acceptance filter enabled the last message reception into this buffer.
01111 = Acceptance Filter 15 (RXF15)
01110 = Acceptance Filter 14 (RXF14)
...
00001 = Acceptance Filter 1 (RXF1)
00000 = Acceptance Filter 0 (RXF0)
RXFUL
R/C-0
Note:
Note 1: These registers are available in Mode 1 and 2 only.
n
5, TXnEN (BSEL0<n>) = 0]
This bit is set by the CAN module upon receiving a message and must be cleared
by software after the buffer is read. As long as RXFUL is set, no new message will
be loaded and buffer will be considered full.
R/W-0
RXM1
‘0’ = Bit is cleared
U = Unimplemented bit, read as ‘0’
R = Readable bit
PIC18F6585/8585/6680/8680
RTRRO
R-0
(1)
FILHIT4
R-0
W = Writable bit
(1)
FILHIT3
R-0
x = Bit is unknown
- n = Value at POR
FILHIT2
R-0
FILHIT1
R-0
DS30491C-page 297
FILHIT0
R-0
bit 0

Related parts for PIC18F6680-I/L