PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 140

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
PEB 3081
PEF 3081
Detailed Register Description
Preliminary
4.1.10
TR_CMD - Transceiver Command Register
Value after reset: 08
H
7
0
TR_
XINF
DPRIO TDDIS
PD
LP_A
0
RD/WR (34)
CMD
Important: This register is only writable if the Layer 1 state machine of the SBCX-X is
disabled (TR_CONF0.L1SW = 1)! With the SBCX-X layer 1 state machine enabled, the
signals from this register are automatically generated, but nevertheless this register can
always be read.
DPRIO can also be written in intelligent NT mode.
XINF ... Transmit INFO
000: Transmit INFO 0
001: reserved
010: Transmit INFO 1 (TE mode) or INFO 2 (NT mode)
011: Transmit INFO 3 (TE mode) or INFO 4 (NT mode)
100: Send continous pulses at 192 kbit/s alternating or 96 kHz rectangular, respectively
(SCP)
101: Send single pulses at 4 kbit/s with alternating polarity corresponding to 2 kHz
fundamental mode (SSP)
11x: reserved
DPRIO ... D-Channel Priority (always writable in Int. NT mode)
0: Priority Class 1 for D channel access on IOM (Int. NT) or on S interface (TE/LT-T)
1: Priority Class 2 for D channel access on IOM (Int. NT) or on S interface (TE/LT-T)
TDDIS ... Transmit Data Disabled (TE mode)
0: The B and D channel data are transparently transmitted on the S/T interface if INFO 3
is being transmitted
1: The B and D channel data are set to logical ’1’ on the S/T interface if INFO 3 is being
transmitted
PD ... Power Down
0: The transceiver is set to operational mode
1: The transceiver is set to power down mode
For general information please refer to
Chapter
3.5.1.2.
Data Sheet
140
2000-09-27

Related parts for PEB3081FV14XP