PEB3081FV14XP Lantiq, PEB3081FV14XP Datasheet - Page 36

PEB3081FV14XP

Manufacturer Part Number
PEB3081FV14XP
Description
Manufacturer
Lantiq
Datasheet

Specifications of PEB3081FV14XP

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Preliminary
The host starts and stops the timer in TIMR.CNT
is operating in count down mode, for TIMR.TMD=1 a periodic interrupt AUXI.TIN is
generated. The timer length (for count down timer) or the timer period (for periodic timer),
respectively, can be configured to a value between 1 - 63 ms (TIMR.CNT).
Figure 11
Data Sheet
TIMR
Timer Register
TMD 0
7
6
5
4
3
CNT
2
1
0
36
Timer Mode
0 : Count Down Timer
1 : Periodic Timer
Timer Count
1 ... 63 : 1 ... 63 ms
65
H
(Figure
0 : Timer off
Description of Functional Blocks
11). If TIMR.TMD=0 the timer
3081_14
PEB 3081
PEF 3081
2000-09-27

Related parts for PEB3081FV14XP