PEB2255H-V13 Infineon Technologies, PEB2255H-V13 Datasheet - Page 230

IC INTERFACE LINE 80-MQFP

PEB2255H-V13

Manufacturer Part Number
PEB2255H-V13
Description
IC INTERFACE LINE 80-MQFP
Manufacturer
Infineon Technologies
Datasheet

Specifications of PEB2255H-V13

Applications
*
Interface
*
Voltage - Supply
*
Package / Case
80-SQFP
Mounting Type
Surface Mount
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
PEB2255H-V13
PEB2255H-V13IN

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PEB2255H-V13
Manufacturer:
Infineon Technologies
Quantity:
10 000
9.4
Receive FIFO (Read)
Reading data from RFIFO can be done in an 8-bit (byte) or 16-bit (word) access
depending on the selected bus interface mode. The LSB is received first from the serial
interface.
The size of the accessible part of RFIFO is determined by programming the bits
CCR1.RFT 1 … 0 (RFIFO threshold level). It can be reduced from 32 bytes (RESET
value) down to 2 bytes (four values: 32, 16, 4, 2 bytes).
Data Transfer
Up to 32 bytes/16 words of received data can be read from the RFIFO following an RPF
or an RME interrupt.
RPF Interrupt: A fixed number of bytes/words to be read (32, 16, 4, 2 bytes). The
message is not yet complete.
RME Interrupt: The message is completely received. The number of valid bytes is
determined by reading the RBCL, RBCH registers.
RFIFO is released by issuing the “Receive Message Complete” command (RMC).
Receive Equalizer Status (Read)
EV1…0...
Data Sheet
RFIFO
RES
RF7
EV1
Detailed Description of E1 Status Registers
7
7
Equalizer Status Valid
These bits informs the user about the current state of the receive
equalization network. Only valid if LIM1.EQON is set.
00… equalizer status not valid, still adapting
01… equalizer status valid
10… equalizer status not valid
11… equalizer status valid but high noise floor
EV0
RES4
230
RES3
RES2
RES1
FALC-LH V1.3
RES0
RF0
E1 Registers
0
0
PEB 2255
(00/01)
2000-07
(4B)

Related parts for PEB2255H-V13