PIC18F65J11-I/PT Microchip Technology, PIC18F65J11-I/PT Datasheet - Page 171

IC PIC MCU FLASH 16KX16 64TQFP

PIC18F65J11-I/PT

Manufacturer Part Number
PIC18F65J11-I/PT
Description
IC PIC MCU FLASH 16KX16 64TQFP
Manufacturer
Microchip Technology
Series
PIC® 18Fr

Specifications of PIC18F65J11-I/PT

Core Size
8-Bit
Program Memory Size
32KB (16K x 16)
Core Processor
PIC
Speed
40MHz
Connectivity
I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, LVD, POR, PWM, WDT
Number Of I /o
51
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
2 V ~ 3.6 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TFQFP
Controller Family/series
PIC18
No. Of I/o's
52
Ram Memory Size
2048Byte
Cpu Speed
40MHz
No. Of Timers
4
Interface
I2C, SPI, USART
Package
64TQFP
Device Core
PIC
Family Name
PIC18
Maximum Speed
40 MHz
Operating Supply Voltage
2.5|3.3 V
Data Bus Width
8 Bit
Number Of Programmable I/os
52
Interface Type
I2C/SPI/USART
On-chip Adc
12-chx10-bit
Number Of Timers
4
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
MA180018 - MODULE PLUG-IN 18F85J11AC162079 - HEADER MPLAB ICD2 18F85J90 64/80AC164327 - MODULE SKT FOR 64TQFP
Eeprom Size
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PIC18F65J11-I/PT
Manufacturer:
Microchip Technology
Quantity:
10 000
TABLE 16-2:
 2010 Microchip Technology Inc.
CCP1 Mode CCP2 Mode
Compare
Compare
Compare
Capture
Capture
Capture
PWM
PWM
PWM
Compare
Compare
Compare
Capture
Capture
Capture
INTERACTIONS BETWEEN CCP1 AND CCP2 FOR TIMER RESOURCES
PWM
PWM
PWM
Each module can use TMR1 or TMR3 as the time base. The time base can be different
for each CCP module.
CCP2 can be configured for the Special Event Trigger to reset TMR1 or TMR3
(depending upon which time base is used). Automatic A/D conversions on trigger event
can also be done. Operation of CCP1 could be affected if it is using the same timer as a
time base.
CCP1 can be configured for the Special Event Trigger to reset TMR1 or TMR3
(depending upon which time base is used). Operation of CCP2 could be affected if it is
using the same timer as a time base.
Either module can be configured for the Special Event Trigger to reset the time base.
Automatic A/D conversions on CCP2 trigger event can be done. Conflicts may occur if
both modules are using the same time base.
None
None
None
None
Both PWMs will have the same frequency and update rate (TMR2 interrupt).
PIC18F85J11 FAMILY
Interaction
DS39774D-page 171