AT90CAN64-16MU Atmel, AT90CAN64-16MU Datasheet - Page 280

IC MCU AVR 64K FLASH 64-QFN

AT90CAN64-16MU

Manufacturer Part Number
AT90CAN64-16MU
Description
IC MCU AVR 64K FLASH 64-QFN
Manufacturer
Atmel
Series
AVR® 90CANr
Datasheets

Specifications of AT90CAN64-16MU

Core Processor
AVR
Core Size
8-Bit
Speed
16MHz
Connectivity
CAN, EBI/EMI, I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
53
Program Memory Size
64KB (64K x 8)
Program Memory Type
FLASH
Eeprom Size
2K x 8
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-VQFN Exposed Pad, 64-HVQFN, 64-SQFN, 64-DHVQFN
Processor Series
AT90CANx
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
4 KB
Interface Type
2-Wire, SPI, USART
Maximum Clock Frequency
16 MHz
Number Of Programmable I/os
53
Number Of Timers
2
Operating Supply Voltage
0.5 V to 0.6 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVRDRAGON, ATSTK500, ATSTK600, ATAVRISP2, ATDVK90CAN1, ATADAPCAN01
Minimum Operating Temperature
- 40 C
On-chip Adc
10 bit, 8 Channel
For Use With
ATSTK600-TQFP64 - STK600 SOCKET/ADAPTER 64-TQFP770-1007 - ISP 4PORT ATMEL AVR MCU SPI/JTAGATDVK90CAN1 - KIT DEV FOR AT90CAN128 MCU
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90CAN64-16MU
Manufacturer:
ATMEL
Quantity:
210
Part Number:
AT90CAN64-16MU
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
21.5.1
21.5.2
21.6
280
ADC Noise Canceler
AT90CAN32/64/128
ADC Input Channels
ADC Voltage Reference
When changing channel selections, the user should observe the following guidelines to ensure
that the correct channel is selected:
When switching to a differential gain channel, the first conversion result may have a poor accu-
racy due to the required settling time for the automatic offset cancellation circuitry. The user
should preferably disregard the first conversion result.
The reference voltage for the ADC (V
ended channels that exceed V
either AV
AV
ated from the internal bandgap reference (V
external AREF pin is directly connected to the ADC, and the reference voltage can be made
more immune to noise by connecting a capacitor between the AREF pin and ground. V
also be measured at the AREF pin with a high impedant voltmeter. Note that V
impedant source, and only a capacitive load should be connected in a system.
If the user has a fixed voltage source connected to the AREF pin, the user may not use the other
reference voltage options in the application, as they will be shorted to the external voltage. If no
external voltage is applied to the AREF pin, the user may switch between AV
reference selection. The first ADC conversion result after switching reference voltage source
may be inaccurate, and the user is advised to discard this result.
If differential channels are used, the selected reference should not be closer to AV
cated in
The ADC features a noise canceler that enables conversion during sleep mode to reduce noise
induced from the CPU core and other I/O peripherals. The noise canceler can be used with ADC
Noise Reduction and Idle mode. To make use of this feature, the following procedure should be
used:
• In Single Conversion mode, always select the channel before starting the conversion. The
• In Free Running mode, always select the channel before starting the first conversion. The
1. Make sure that the ADC is enabled and is not busy converting. Single Conversion
2. Enter ADC Noise Reduction mode (or Idle mode). The ADC will start a conversion once
3. If no other interrupts occur before the ADC conversion completes, the ADC interrupt
CC
channel selection may be changed one ADC clock cycle after writing one to ADSC. However,
the simplest method is to wait for the conversion to complete before changing the channel
selection.
channel selection may be changed one ADC clock cycle after writing one to ADSC. However,
the simplest method is to wait for the first conversion to complete, and then change the
channel selection. Since the next conversion has already started automatically, the next
result will reflect the previous channel selection. Subsequent conversions will reflect the new
channel selection.
mode must be selected and the ADC conversion complete interrupt must be enabled.
the CPU has been halted.
will wake up the CPU and execute the ADC Conversion Complete interrupt routine. If
is connected to the ADC through a passive switch. The internal 2.56V reference is gener-
Table 26-6 on page
CC
, internal 2.56V reference, or external AREF pin.
374.
REF
will result in codes close to 0x3FF. V
REF
) indicates the conversion range for the ADC. Single
BG
) through an internal amplifier. In either case, the
REF
can be selected as
CC
7679H–CAN–08/08
and 2.56V as
REF
CC
than indi-
is a high
REF
can

Related parts for AT90CAN64-16MU