HD64F2612FA20 Renesas Electronics America, HD64F2612FA20 Datasheet - Page 383

IC H8S MCU FLASH 128K 80QFP

HD64F2612FA20

Manufacturer Part Number
HD64F2612FA20
Description
IC H8S MCU FLASH 128K 80QFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2600r
Datasheets

Specifications of HD64F2612FA20

Core Processor
H8S/2600
Core Size
16-Bit
Speed
20MHz
Connectivity
CAN, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
43
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 12x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
80-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F2612FA20
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Part Number:
HD64F2612FA20J
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
No
No
Read receive data in RDR, and
clear RDRF flag in SSR to 0
PER ∨ FER ∨ ORER = 1
Clear RE bit in SCR to 0
Read RDRF flag in SSR
Read ORER, PER, and
Figure 14.9 Sample Serial Reception Data Flowchart (1)
All data received?
FER flags in SSR
Start reception
Initialization
RDRF = 1
<End>
Yes
Yes
No
(Continued on next page)
Error processing
Yes
[1]
[2]
[4]
[5]
[3]
Section 14 Serial Communication Interface (SCI)
[1] SCI initialization:
[2] [3] Receive error processing and break
[4] SCI status check and receive data read:
[5] Serial reception continuation procedure:
Rev. 7.00 Sep. 11, 2009 Page 347 of 566
The RxD pin is automatically
designated as the receive data input
pin.
detection:
If a receive error occurs, read the
ORER, PER, and FER flags in SSR to
identify the error. After performing the
appropriate error processing, ensure
that the ORER, PER, and FER flags are
all cleared to 0. Reception cannot be
resumed if any of these flags are set to
1. In the case of a framing error, a
break can be detected by reading the
value of the input port corresponding to
the RxD pin.
Read SSR and check that RDRF = 1,
then read the receive data in RDR and
clear the RDRF flag to 0. Transition of
the RDRF flag from 0 to 1 can also be
identified by an RXI interrupt.
To continue serial reception, before the
stop bit for the current frame is
received, read the RDRF flag, read
RDR, and clear the RDRF flag to 0.
The RDRF flag is cleared automatically
when DTC is activated by an RXI
interrupt and the RDR value is read.
REJ09B0211-0700

Related parts for HD64F2612FA20