DF2377RVFQ33 Renesas Electronics America, DF2377RVFQ33 Datasheet - Page 166

IC H8S MCU FLASH 3V 384K 144LQFP

DF2377RVFQ33

Manufacturer Part Number
DF2377RVFQ33
Description
IC H8S MCU FLASH 3V 384K 144LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of DF2377RVFQ33

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
97
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
24K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 6x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2377RVFQ33
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
DF2377RVFQ33V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
DF2377RVFQ33W
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
DF2377RVFQ33WV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 4 Exception Handling
4.4
Traces are enabled in interrupt control mode 2. Trace mode is not activated in interrupt control
mode 0, irrespective of the state of the T bit. For details on interrupt control modes, see section 5,
Interrupt Controller.
If the T bit in EXR is set to 1, trace mode is activated. In trace mode, a trace exception occurs on
completion of each instruction. Trace mode is not affected by interrupt masking. Table 4.3 shows
the state of CCR and EXR after execution of trace exception handling. Trace mode is canceled by
clearing the T bit in EXR to 0. The T bit saved on the stack retains its value of 1, and when control
is returned from the trace exception handling routine by the RTE instruction, trace mode resumes.
Trace exception handling is not carried out after execution of the RTE instruction.
Interrupts are accepted even within the trace exception handling routine.
Table 4.3
Legend:
1:
0:
—: Retains value prior to execution.
4.5
Interrupts are controlled by the interrupt controller. The interrupt controller has two interrupt
control modes and can assign interrupts other than NMI to eight priority/mask levels to enable
multiplexed interrupt control. The source to start interrupt exception handling and the vector
address differ depending on the product. For details, refer to section 5, Interrupt Controller.
The interrupt exception handling is as follows:
1. The values in the program counter (PC), condition code register (CCR), and extended register
2. The interrupt mask bit is updated and the T bit is cleared to 0.
3. A vector address corresponding to the interrupt source is generated, the start address is loaded
Rev.7.00 Mar. 18, 2009 page 98 of 1136
REJ09B0109-0700
(EXR) are saved in the stack.
from the vector table to the PC, and program execution starts from that address.
Interrupt Control Mode
Set to 1
Cleared to 0
Trace Exception Handling
Interrupt Exception Handling
Status of CCR and EXR after Trace Exception Handling
0
2
1
I
Trace exception handling cannot be used.
CCR
UI
I2 to I0
EXR
T
0

Related parts for DF2377RVFQ33