DF2377RVFQ33 Renesas Electronics America, DF2377RVFQ33 Datasheet - Page 772

IC H8S MCU FLASH 3V 384K 144LQFP

DF2377RVFQ33

Manufacturer Part Number
DF2377RVFQ33
Description
IC H8S MCU FLASH 3V 384K 144LQFP
Manufacturer
Renesas Electronics America
Series
H8® H8S/2300r
Datasheet

Specifications of DF2377RVFQ33

Core Processor
H8S/2000
Core Size
16-Bit
Speed
33MHz
Connectivity
I²C, IrDA, SCI, SmartCard
Peripherals
DMA, POR, PWM, WDT
Number Of I /o
97
Program Memory Size
384KB (384K x 8)
Program Memory Type
FLASH
Ram Size
24K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 3.6 V
Data Converters
A/D 16x10b; D/A 6x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
144-LQFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DF2377RVFQ33
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
DF2377RVFQ33V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
DF2377RVFQ33W
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
DF2377RVFQ33WV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 15 Serial Communication Interface (SCI, IrDA)
Bit
5
4
Rev.7.00 Mar. 18, 2009 page 704 of 1136
REJ09B0109-0700
Bit Name
ORER
FER
Initial Value
0
0
R/W
R/(W) *
R/(W) *
Description
Overrun Error
Indicates that an overrun error occurred while
receiving and the reception has ended abnormally.
[Setting condition]
[Clearing condition]
Framing Error
Indicates that a framing error occurred while
receiving in asynchronous mode and the reception
has ended abnormally.
[Setting condition]
[Clearing condition]
When the next serial reception is completed
while RDRF = 1
The receive data prior to the overrun error is
retained in RDR, and the data received
subsequently is lost. Also, subsequent serial
reception cannot be continued while the ORER
flag is set to 1. In clocked synchronous mode,
serial transmission cannot be continued, either.
When 0 is written to ORER after reading ORER
= 1
The ORER flag is not affected and retains its
previous state when the RE bit in SCR is
cleared to 0.
When the stop bit is 0
In 2-stop-bit mode, only the first stop bit is
checked for a value of 0; the second stop bit is
not checked. If a framing error occurs, the
receive data is transferred to RDR but the
RDRF flag is not set. Also, subsequent serial
reception cannot be continued while the FER
flag is set to 1. In clocked synchronous mode,
serial transmission cannot be continued, either.
When 0 is written to FER after reading FER = 1
The FER flag is not affected and retains its
previous state when the RE bit in SCR is
cleared to 0.

Related parts for DF2377RVFQ33