ics1893cy-10 Integrated Device Technology, ics1893cy-10 Datasheet - Page 93

no-image

ics1893cy-10

Manufacturer Part Number
ics1893cy-10
Description
3.3-v 10base-t/100base-tx Integrated Phyceiver
Manufacturer
Integrated Device Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ics1893cy-10LF
Manufacturer:
IDT
Quantity:
469
Part Number:
ics1893cy-10LF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ics1893cy-10LFT
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
7.13.2 Polarity Reversed (bit 18.14)
7.13.3 ICS Reserved (bits 18.13:6)
7.13.4 Jabber Inhibit (bit 18.5)
7.13.5 ICS Reserved (bit 18.4)
7.13.6 Auto Polarity Inhibit (bit 18.3)
ICS1893CY-10 Rev 1/07
The Polarity Reversed bit is used to inform an STA whether the ICS1893CY-10 has detected that the
signals on the Twisted-Pair Receive Pins (TP_RXP and TP_RXN) are reversed. When the signal polarity
is:
Note:
See
The Jabber Inhibit bit allows an STA to disable Jabber Detection. When an STA sets this bit to:
See
The Auto Polarity Inhibit bit allows an STA to prevent the automatic correction of a polarity reversal on the
Twisted-Pair Receive pins (TP_RXP and TP_RXN). If an STA sets this bit to logic:
Note:
Correct, the ICS1893CY-10 sets bit 18.14 to a logic zero.
Reversed, the ICS1893CY-10 sets bit 18.14 to logic one.
Zero, the ICS1893CY-10 enables 10Base-T Jabber checking.
One, the ICS1893CY-10 disables its check for a Jabber condition during data transmission.
Zero (the default), the ICS1893CY-10 automatically corrects a polarity reversal on the Twisted-Pair
Receive pins.
One, the ICS1893CY-10 either disables or inhibits the automatic correction of reversed Twisted-Pair
Receive pins.
ICS1893CY-10 - Release
Section 7.11.2, “ICS Reserved (bits
Section 7.11.2, “ICS Reserved (bits
The ICS1893CY-10 can detect this situation and perform all its operations normally, independent of
the reversal.
The ICS1893CY-10 will not complete the Auto-MDIX function for an inverted polarity cable.
This is a rare event with modern manufactured cables. Full Auto-Negotiation and Auto
Polarity Correction will complete when the Auto-MDIX function is disabled. Software control
for the Auto-MDIX function is available in MDIO Register 19 Bits 9:8.
Copyright © 2007, Integrated Device Technology, Inc.
16.14:11)”, the text for which also applies here.
16.14:11)”, the text for which also applies here.
All rights reserved.