ics1893cy-10 Integrated Device Technology, ics1893cy-10 Datasheet - Page 96

no-image

ics1893cy-10

Manufacturer Part Number
ics1893cy-10
Description
3.3-v 10base-t/100base-tx Integrated Phyceiver
Manufacturer
Integrated Device Technology
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ics1893cy-10LF
Manufacturer:
IDT
Quantity:
469
Part Number:
ics1893cy-10LF
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
Part Number:
ics1893cy-10LFT
Manufacturer:
IDT, Integrated Device Technology Inc
Quantity:
10 000
7.14.1 Node Configuration (bit 19.15)
7.14.2 Hardware/Software Priority Status (bit 19.14)
7.14.3 Remote Fault (bit 19.13)
7.14.4 ICS Reserved (bits 19.12:10)
7.14.5 Auto-MDI/MDIX (bits 19. 9:8) (New)
ICS1893CY-10 Rev 1/07
The Node Configuration bit indicates the NOD/MODE.
The Hardware/Software Priority Status bit indicates the SW mode.
The ISO/IEC specification defines bit 5.13 as the Remote Fault bit, and bit 19.13 is functionally identical to
bit 5.13. The Remote Fault bit is set based on the Link Control Word received from the remote link partner.
When this bit is a logic:
See
The ICS1893CY-10 includes the Auto-MDI/MDIX crossover feature. The Auto-MDI/MDIX feature
automatically selects the correct MDI or MDIX configuration to match the cable plant by automatically
swapping transmit and receive signal pairs at the PHY. Auto-MDI/MDIX is defaulted on but may be disabled
for test purposes using either the AMDIX_EN (pin 10) or by writing (bits 19. 9:8). See Table 7-22 for
AMDIX_EN (19,9) and MDI_MODE (19,8) operation.
When AMDIX_EN (bit 19,9) is set to 0, the twisted pair transmit/receive is forced by the MDI_MODE bit
(19,8).
Note:
Table 7-22. AMDIX_EN (Pin 10) and Control Bits 19. 9:8
In Node mode:
The ICS1893CY-10 will only operate in the Node Configuration.
The (MDIO) register bits control the ICS1893CY-10 configuration.
The ICS1893CY-10 will only operate in the Software Configuration.
Zero, it indicates the remote link partner does not detect a Link Fault.
One, it indicates to an STA that the remote link partner detects a Link Fault.
– The SQE Test default setting is enabled.
– The Carrier Sense signal (CRS) is asserted in response to either transmit or receive activity.
Section 7.11.2, “ICS Reserved (bits
ICS1893CY-10 Data Sheet - Release
AMDIX_EN
Holding (Pin 3) AMDIX_EN low will also disable the Auto_MDIX function and force pins TP_AP and
TP_AN to be the transmit pair and TP_BP and TP_BN to be the receive pair. AMDIX_EN has a
built in 50K Ohm internal pull-up.
(Pin 3)
x
x
0
Copyright © 2007, Integrated Device Technology, Inc.
AMDIX_EN
[Reg 19:9]
0
0
1
16.14:11)”, the text for which also applies here.
All rights reserved.
96
MDI_MODE
[Reg 19:8]
0
1
x
Chapter 7 Management Register Set
Configuration
Tx/Rx MDI
straight
straight
cross

Related parts for ics1893cy-10