HD6412332 RENESAS [Renesas Technology Corp], HD6412332 Datasheet - Page 640

no-image

HD6412332

Manufacturer Part Number
HD6412332
Description
Renesas 16-Bit Single-Chip Microcomputer H8S Family/H8S/2300 Series
Manufacturer
RENESAS [Renesas Technology Corp]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD6412332
Manufacturer:
SMD
Quantity:
6
Part Number:
HD6412332FC25V
Manufacturer:
ALLEGRO
Quantity:
4 340
Part Number:
HD6412332VFC25V
Manufacturer:
RENESAS/瑞萨
Quantity:
20 000
Bit 6—Receive Data Register Full (RDRF): Indicates that the received data is stored in RDR.
Bit 6
RDRF
0
1
Note: RDR and the RDRF flag are not affected and retain their previous values when an error is
Bit 5—Overrun Error (ORER): Indicates that an overrun error occurred during reception,
causing abnormal termination.
Bit 5
ORER
0
1
Notes: 1. The ORER flag is not affected and retains its previous state when the RE bit in SCR is
Rev.4.00 Sep. 07, 2007 Page 610 of 1210
REJ09B0245-0400
detected during reception or when the RE bit in SCR is cleared to 0.
If reception of the next data is completed while the RDRF flag is still set to 1, an overrun
error will occur and the receive data will be lost.
2. The receive data prior to the overrun error is retained in RDR, and the data received
cleared to 0.
subsequently is lost. Also, subsequent serial reception cannot be continued while the
ORER flag is set to 1. In synchronous mode, serial transmission cannot be continued,
either.
Description
[Clearing conditions]
[Setting condition]
When serial reception ends normally and receive data is transferred from RSR to RDR
Description
[Clearing condition]
When 0 is written to ORER after reading ORER = 1
[Setting condition]
When the next serial reception is completed while RDRF = 1 *
When 0 is written to RDRF after reading RDRF = 1
When the DMAC or DTC is activated by an RXI interrupt and reads data from RDR
2
(Initial value) *
(Initial value)
1

Related parts for HD6412332