AT90PWM216-16SE ATMEL [ATMEL Corporation], AT90PWM216-16SE Datasheet - Page 273

no-image

AT90PWM216-16SE

Manufacturer Part Number
AT90PWM216-16SE
Description
8-bit Microcontroller with 16K Bytes In-System Programmable flash
Manufacturer
ATMEL [ATMEL Corporation]
Datasheet
24.6
7710D–AVR–08/09
Addressing the Flash During Self-Programming
will auto-clear upon completion of a Page Write, or if no SPM instruction is executed within four
clock cycles. The CPU is halted during the entire Page Write operation if the NRWW section is
addressed.
• Bit 1 – PGERS: Page Erase
If this bit is written to one at the same time as SPMEN, the next SPM instruction within four clock
cycles executes Page Erase. The page address is taken from the high part of the Z-pointer. The
data in R1 and R0 are ignored. The PGERS bit will auto-clear upon completion of a Page Erase,
or if no SPM instruction is executed within four clock cycles. The CPU is halted during the entire
Page Write operation if the NRWW section is addressed.
• Bit 0 – SPMEN: Self Programming Enable
This bit enables the SPM instruction for the next four clock cycles. If written to one together with
either RWWSRE, BLBSET, PGWRT or PGERS, the following SPM instruction will have a spe-
cial meaning, see description above. If only SPMEN is written, the following SPM instruction will
store the value in R1:R0 in the temporary page buffer addressed by the Z-pointer. The LSB of
the Z-pointer is ignored. The SPMEN bit will auto-clear upon completion of an SPM instruction,
or if no SPM instruction is executed within four clock cycles. During Page Erase and Page Write,
the SPMEN bit remains high until the operation is completed.
Writing any other combination than “10001”, “01001”, “00101”, “00011” or “00001” in the lower
five bits will have no effect.
The Z-pointer is used to address the SPM commands.
Since the Flash is organized in pages (see
be treated as having two different sections. One section, consisting of the least significant bits, is
addressing the words within a page, while the most significant bits are addressing the pages.
This is1 shown in
addressed independently. Therefore it is of major importance that the Boot Loader software
addresses the same page in both the Page Erase and Page Write operation. Once a program-
ming operation is initiated, the address is latched and the Z-pointer can be used for other
operations.
The only SPM operation that does not use the Z-pointer is Setting the Boot Loader Lock bits.
The content of the Z-pointer is ignored and will have no effect on the operation. The LPM
instruction does also use the Z-pointer to store the address. Since this instruction addresses the
Flash byte-by-byte, also the LSB (bit Z0) of the Z-pointer is used.
Bit
ZH (R31)
ZL (R30)
Z15
15
Z7
7
Figure
Z14
14
Z6
6
24-3. Note that the Page Erase and Page Write operations are
Z13
13
Z5
5
Table 25-11 on page
Z12
12
Z4
4
Z11
11
Z3
3
AT90PWM216/316
Z10
10
Z2
2
287), the Program Counter can
Z9
Z1
9
1
Z8
Z0
8
0
273

Related parts for AT90PWM216-16SE