MT90520AG ZARLINK [Zarlink Semiconductor Inc], MT90520AG Datasheet - Page 128

no-image

MT90520AG

Manufacturer Part Number
MT90520AG
Description
8-Port Primary Rate Circuit Emulation AAL1 SAR
Manufacturer
ZARLINK [Zarlink Semiconductor Inc]
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
MT90520AG
Quantity:
19
Address: 2042 (Hex)
Label: SRSER
Reset Value: 0000 (Hex)
SDT_MIS_ROLL_
REFRAME_ROLL
SDT_HDR_ROLL
SDT_SEQ_ROLL
POINTER_OUT_
PARITY_ROLL_
OF_RANGE_SE
CAS_CHANGE_
SDT_UNDER_
SDT_REASS_
SDT_OVER_
SDT_LOST_
ROLL_SE
ROLL_SE
ROLL_SE
ROLL_SE
Reserved
Label
_SE
_SE
_SE
SE
SE
SE
Position
15:11
Bit
10
0
1
2
3
4
5
6
7
8
9
Table 52 - SDT Reassembly Service Enable Register
Type
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/O
When set, the assertion of the Reassembled Cells Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the AAL1 Header Byte Error Counter Rollover status bit in an
SDT Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in
the SDT Reassembly Status Register at 2044h.
When set, the assertion of the AAL1 Sequence Error Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the Lost Cells Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the Misinserted Cells Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the Pointer Reframes Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the Pointer Parity Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the Buffer Underrun Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the Buffer Overrun Counter Rollover status bit in an SDT
Reassembly Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the
SDT Reassembly Status Register at 2044h.
When set, the assertion of the Pointer Out-of-Range status bit in an SDT Reassembly
Control Structure will cause the SDT_RXSAR_STATUS bit to be set in the SDT
Reassembly Status Register at 2044h.
When set, the assertion of the CAS Changed status bit in an SDT Reassembly Control
Structure will cause the SDT_RXSAR_STATUS bit to be set in the SDT Reassembly
Status Register at 2044h.
Always reads “0000_0”.
Zarlink Semiconductor Inc.
MT90520
128
Description
Data Sheet

Related parts for MT90520AG