ATSAM3X4EA-AU Atmel, ATSAM3X4EA-AU Datasheet - Page 129

no-image

ATSAM3X4EA-AU

Manufacturer Part Number
ATSAM3X4EA-AU
Description
ARM Microcontrollers - MCU QFP144,GREEN, IND TEMP, MRL A
Manufacturer
Atmel
Datasheet

Specifications of ATSAM3X4EA-AU

Rohs
yes
Core
ARM Cortex M3
Processor Series
SAM3X
Data Bus Width
32 bit
Maximum Clock Frequency
84 MHz
Program Memory Size
256 KB
Data Ram Size
64 KB
On-chip Adc
Yes
Operating Supply Voltage
2.4 V to 3.6 V
Operating Temperature Range
- 40 C to +85 C
Package / Case
LQFP-144
Mounting Style
SMD/SMT
Factory Pack Quantity
60

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ATSAM3X4EA-AU
Manufacturer:
Atmel
Quantity:
10 000
12.14.1
12.14.1.1
12.14.1.2
12.14.1.3
12.14.1.4
12.14.1.5
11057B–ATARM–28-May-12
11057B–ATARM–28-May-12
MUL
MLA
MULS
MULLT
MLS
MUL, MLA, and MLS
Syntax
Operation
Restrictions
Condition flags
Examples
R10, R2, R5
R10, R2, R1, R5 ; Multiply with accumulate, R10 = (R2 x R1) + R5
R0, R2, R2
R2, R3, R2
R4, R5, R6, R7
Multiply, Multiply with Accumulate, and Multiply with Subtract, using 32-bit operands, and pro-
ducing a 32-bit result.
where:
cond
S
result of the operation, see
Rd
Rn, Rm
Ra
The MUL instruction multiplies the values from Rn and Rm, and places the least significant 32
bits of the result in Rd.
The MLA instruction multiplies the values from Rn and Rm, adds the value from Ra, and places
the least significant 32 bits of the result in Rd.
The MLS instruction multiplies the values from Rn and Rm, subtracts the product from the value
from Ra, and places the least significant 32 bits of the result in Rd.
The results of these instructions do not depend on whether the operands are signed or
unsigned.
In these instructions, do not use SP and do not use PC.
If you use the S suffix with the MUL instruction:
If S is specified, the MUL instruction:
• Rd, Rn, and Rm must all be in the range R0 to R7
• Rd must be the same as Rm
• you must not use the cond suffix.
• updates the N and Z flags according to the result
• does not affect the C and V flags.
MUL{S}{cond} {Rd,} Rn, Rm ; Multiply
MLA{cond} Rd, Rn, Rm, Ra
MLS{cond} Rd, Rn, Rm, Ra
; Multiply, R10 = R2 x R5
; Multiply with flag update, R0 = R2 x R2
; Conditionally multiply, R2 = R3 x R2
; Multiply with subtract, R4 = R7 - (R5 x R6)
is an optional condition code, see
is an optional suffix. If S is specified, the condition code flags are updated on the
is the destination register. If Rd is omitted, the destination register is Rn.
are registers holding the values to be multiplied.
is a register holding the value to be added or subtracted from.
“Conditional execution” on page
; Multiply with accumulate
; Multiply with subtract
“Conditional execution” on page
100.
SAM3X/A
SAM3X/A
100.
129
129

Related parts for ATSAM3X4EA-AU