Z16F2800100ZCOG Zilog, Z16F2800100ZCOG Datasheet - Page 119

DEV KIT FOR Z16F ZNEO

Z16F2800100ZCOG

Manufacturer Part Number
Z16F2800100ZCOG
Description
DEV KIT FOR Z16F ZNEO
Manufacturer
Zilog
Series
ZNEO™r
Type
MCUr

Specifications of Z16F2800100ZCOG

Contents
Evaluation Board, Software and Documentation
For Use With/related Products
Z16F Series
For Use With
269-4661 - KIT ACC ETHERNET SMART CABLE
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
269-4537
PS022008-0810
Capture Elapsed Time (s)
2. Write to the timer reload high and low byte registers to set the starting count value
3. Write to the timer reload high and low byte registers to set the Reload value.
4. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing
5. Configure the associated GPIO port pin for the timer input alternate function.
6. Write to the timer control 1 register to enable the timer. In CAPTURE and CAPTURE
In CAPTURE modes, the elapsed time from timer start to Capture event is calculated
using the following equation (start value = 1):
COMPARE Mode
In COMPARE mode, the timer counts up to the 16-bit Compare value stored in the timer
reload high and low byte registers. After reaching the compare value, the timer generates
an interrupt and counting continues (the timer value is not reset to
output alternate function is enabled, the timer output pin changes state (from Low to High
or High to Low).
If the timer reaches
Follow the steps below to configure timer for COMPARE mode and initiate the count:
1. Write to the timer control registers to:
2. Write to the timer high and low byte registers to set the starting count value.
3. Write to the timer reload high and low byte registers to set the Compare value.
4. Enable the timer interrupt, if appropriate, and set the timer interrupt priority by writing
5. When using the timer output function, configure the associated GPIO port pin for the
(typically
to the relevant interrupt registers.
RESTART modes, the timer begins counting. In CAPTURE COMPARE mode the
timer does not start counting until the first appropriate input transition occurs.
to the relevant interrupt registers.
timer output alternate function.
Configure the timer interrupt to be generated at the input capture event, the reload
event or both by setting
Disable the timer.
Configure the timer for COMPARE mode.
Set the prescale value.
Set the initial logic level (High or Low) for the timer output alternate function, if
required.
0001H
FFFFH
).
P R E L I M I N A R Y
=
, the timer rolls over to
------------------------------------------------------------------------------------------------------------- -
Capture Value Start Value + 1
TICONFIG
System Clock Frequency (Hz)
field.
0000H
and continues counting.
Product Specification
0001H
ZNEO
Prescale
). If the timer
Z16F Series
Timers
104

Related parts for Z16F2800100ZCOG