C8051F040DK Silicon Laboratories Inc, C8051F040DK Datasheet - Page 98

DEV KIT FOR F040/F041/F042/F043

C8051F040DK

Manufacturer Part Number
C8051F040DK
Description
DEV KIT FOR F040/F041/F042/F043
Manufacturer
Silicon Laboratories Inc
Type
MCUr
Datasheets

Specifications of C8051F040DK

Contents
Evaluation Board, Power Supply, USB Cables, Adapter and Documentation
Processor To Be Evaluated
C8051F04x
Interface Type
USB
Silicon Manufacturer
Silicon Labs
Core Architecture
8051
Silicon Core Number
C8051F040
Silicon Family Name
C8051F04x
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With/related Products
Silicon Laboratories C8051 F040, 041, 042, 043 MCUs
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
336-1205

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
C8051F040DK
Manufacturer:
SiliconL
Quantity:
9
C8051F040/1/2/3/4/5/6/7
98
Bit7:
Bit6:
Bit5:
Bit4:
Bits3-1:
Bit0:
An important note about external convert start (CNVSTR0 and CNVSTR2): If CNVSTR2 is enabled in
AD2EN
R/W
Bit7
AD2EN: ADC2 Enable Bit.
0: ADC2 Disabled. ADC2 is in low-power shutdown.
1: ADC2 Enabled. ADC2 is active and ready for data conversions.
AD2TM: ADC2 Track Mode Bit.
0: Normal Track Mode: When ADC2 is enabled, tracking is continuous unless a conversion is in
process.
1: Low-power Track Mode: Tracking defined by AD2CM2-0 bits (see below).
AD2INT: ADC2 Conversion Complete Interrupt Flag.
This flag must be cleared by software.
0: ADC2 has not completed a data conversion since the last time this flag was cleared.
1: ADC2 has completed a data conversion.
AD2BUSY: ADC2 Busy Bit.
Read:
0: ADC2 Conversion is complete or a conversion is not currently in progress. AD2INT is set to
logic 1 on the falling edge of AD2BUSY.
1: ADC2 Conversion is in progress.
Write:
0: No Effect.
1: Initiates ADC2 Conversion if AD2CM2-0 = 000b
AD2CM2-0: ADC2 Start of Conversion Mode Select.
AD2TM = 0:
000: ADC2 conversion initiated on every write of ‘1’ to AD2BUSY.
001: ADC2 conversion initiated on overflow of Timer 3.
010: ADC2 conversion initiated on rising edge of external CNVSTR2 or CNVSTR0.
011: ADC2 conversion initiated on overflow of Timer 2.
1xx: ADC2 conversion initiated on write of ‘1’ to AD0BUSY (synchronized with ADC0 software-
commanded conversions).
AD2TM = 1:
000: Tracking initiated on write of ‘1’ to AD2BUSY and lasts 3 SAR2 clocks, followed by conver-
sion.
001: Tracking initiated on overflow of Timer 3 and lasts 3 SAR2 clocks, followed by conversion.
010: ADC2 tracks only when CNVSTR2 (or CNVSTR0, See Section 7.2.1) input is logic low; con-
version starts on rising CNVSTR2 edge.
011: Tracking initiated on overflow of Timer 2 and lasts 3 SAR2 clocks, followed by conversion.
1xx: Tracking initiated on write of ‘1’ to AD0BUSY and lasts 3 SAR2 clocks, followed by conver-
sion.
AD2WINT: ADC2 Window Compare Interrupt Flag.
0: ADC2 window comparison data match has not occurred since this flag was last cleared.
1: ADC2 window comparison data match has occurred. This flag must be cleared in software.
the digital crossbar (
on page 204
CNVSTR0 is enabled in the digital crossbar and CNVSTR2 is not enabled, then CNVSTR0 may
serve as the start of conversion for both ADC0 and ADC2.
AD2TM
R/W
Bit6
SFR Definition 7.4. ADC2CN: ADC2 Control
AD2INT AD2BUSY AD2CM2 AD2CM1
), CNVSTR2 will be the external convert start signal for ADC2. However, if only
R/W
Bit5
Section “17.1. Ports 0 through 3 and the Priority Crossbar Decoder”
R/W
Bit4
Rev. 1.5
R/W
Bit3
R/W
Bit2
AD2CM0
R/W
Bit1
SFR Address:
AD2WINT 00000000
SFR Page:
R/W
Bit0
0xE8
2
Reset Value

Related parts for C8051F040DK