PSB21150FV14XT Lantiq, PSB21150FV14XT Datasheet - Page 122

PSB21150FV14XT

Manufacturer Part Number
PSB21150FV14XT
Description
Manufacturer
Lantiq
Datasheet

Specifications of PSB21150FV14XT

Number Of Line Interfaces
1
Control Interface
HDLC
Lead Free Status / Rohs Status
Compliant
Figure 69
3.7.3.3
As a master device the IPAC-X can program and control other devices attached to the
IOM-2 interface. The master mode is selected by default if one of the possible
microcontroller interfaces are selected. The monitor data is written by the
microprocessor in the MOX register and transmitted via IOM-2 DD (DU) line to the
programmed/controlled device, e.g. ARCOFI-BA PSB 2161 or IEC-Q TE PSB 21911.
The transfer of the commands in the MON channel is regulated by the handshake
protocol mechanism with MX, MR which is described in the previous
If the transmitted command was a read command the slave device responds by sending
the requested data.
The data structure of the transmitted monitor message depends on the device which is
programmed. Therefore the first byte of the message is a specific address code which
contains in the higher nibble a MONITOR channel address to identify different devices.
The length of the messages depends on the accessed device and the type of MONITOR
command.
Data Sheet
IOM -2 Frame No.
MR (DU)
MX (DD)
MONITOR Channel Programming as a Master Device
Monitor Channel, Normal End of Transmission
1
0
1
0
1
2
122
3
4
Description of Functional Blocks
5
6
mon_norm.vsd
EOM
7
PSB/PSF 21150
Chapter
8
2003-01-30
3.7.3.1.
IPAC-X

Related parts for PSB21150FV14XT