HD64F3337YCP16 Renesas Electronics America, HD64F3337YCP16 Datasheet - Page 298

no-image

HD64F3337YCP16

Manufacturer Part Number
HD64F3337YCP16
Description
IC H8 MCU FLASH 60K 84PLCC
Manufacturer
Renesas Electronics America
Series
H8® H8/300r
Datasheets

Specifications of HD64F3337YCP16

Core Processor
H8/300
Core Size
8-Bit
Speed
16MHz
Connectivity
Host Interface, I²C, SCI
Peripherals
POR, PWM, WDT
Number Of I /o
74
Program Memory Size
60KB (60K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
4.5 V ~ 5.5 V
Data Converters
A/D 8x10b; D/A 2x8b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
84-PLCC
Package
84PLCC
Family Name
H8
Maximum Speed
16 MHz
Operating Supply Voltage
5 V
Data Bus Width
8 Bit
Number Of Programmable I/os
74
Interface Type
HIF/I2C/SCI
On-chip Adc
8-chx10-bit
On-chip Dac
2-chx8-bit
Number Of Timers
3
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3337YCP16
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3337YCP16V
Manufacturer:
COILMASTER
Quantity:
30 000
Part Number:
HD64F3337YCP16V
Manufacturer:
RENESAS
Quantity:
1 029
Part Number:
HD64F3337YCP16V
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Receiving Serial Data: Follow the procedure in figure 12.7 for receiving serial data.
266
1
2
3
Read receive data from RDR,
and clear RDRF bit to 0
Read ORER, PER, and
Read RDRF bit in SSR
Clear RE to 0 in SCR
Start error handling
process error, and
Discriminate and
Start receiving
PER
FER in SSR
RDRF = 1?
receiving?
clear flags
ORER = 1?
FER = 1?
Finished
Initialize
in SSR
Return
End
RER
Yes
Yes
No
No
Figure 12.7 Sample Flowchart for Receiving Serial Data
Yes
No
Yes
No
Error handling
Break?
No
4
Clear RE to 0
in SCR
1.
2.
3.
4.
End
Yes
SCI initialization: the receive data function of the RxD
pin is selected automatically.
To continue receiving serial data: read RDR and
clear RDRF to 0 before the stop bit of the current
frame is received.
SCI status check and receive data read: read the
serial status register (SSR), check that RDRF is set
to 1, then read receive data from the receive data
register (RDR) and clear RDRF to 0. Transition of
the RDRF bit from 0 to 1 can be reported by an RXI
interrupt.
Receive error handling and break detection: if a
receive error occurs, read the ORER, PER, and
FER bits in SSR to identify the error. After executing
the necessary error handling, clear ORER, PER, and
FER all to 0. Transmitting and receiving cannot
resume if ORER, PER, or FER remains set to 1.
When a framing error occurs, the RxD pin can be
read to detect the break state.