MFRC52301HN1,151 NXP Semiconductors, MFRC52301HN1,151 Datasheet - Page 17

IC MIFARE READER 32-HVQFN

MFRC52301HN1,151

Manufacturer Part Number
MFRC52301HN1,151
Description
IC MIFARE READER 32-HVQFN
Manufacturer
NXP Semiconductors
Series
MIFARE®r
Datasheets

Specifications of MFRC52301HN1,151

Frequency
13.56MHz
Package / Case
32-VQFN Exposed Pad, 32-HVQFN, 32-SQFN, 32-DHVQFN
Operating Current
7 mA
Operating Voltage
2.5 V to 3.6 V
Product
RFID Readers
Wireless Frequency
13.56 MHz
Interface Type
RS-232, I2C
Data Rate
100 Kbps
Operating Temperature Range
- 25 C to +85 C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
-
Rf Type
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
568-4766
935282956151
MFRC52301HN1
NXP Semiconductors
MFRC523_32
Product data sheet
PUBLIC
8.3.4.1 Data validity
8.3.4.2 START and STOP conditions
8.3.4.3 Byte format
Data on the SDA line must be stable during the HIGH clock period. The HIGH or LOW
state of the data line must only change when the clock signal on SCL is LOW.
To manage the data transfer on the I
are defined.
The I
after the START condition. The bus is free again a certain time after the STOP condition.
The bus stays busy if a repeated START (Sr) is generated instead of a STOP condition.
The START (S) and repeated START (Sr) conditions are functionally identical. Therefore,
S is used as a generic term to represent both the START (S) and repeated START (Sr)
conditions.
Each byte must be followed by an acknowledge bit. Data is transferred with the MSB first;
see
but must meet the read/write cycle format.
Fig 12. Bit transfer on the I
Fig 13. START and STOP conditions
A START condition is defined with a HIGH-to-LOW transition on the SDA line while
SCL is HIGH.
A STOP condition is defined with a LOW-to-HIGH transition on the SDA line while
SCL is HIGH.
Figure
2
C-bus master always generates the START and STOP conditions. The bus is busy
SDA
SCL
16. The number of transmitted bytes during one data transfer is unrestricted
START condition
SDA
SCL
S
Rev. 3.2 — 12 January 2010
2
C-bus
115232
data valid
data line
stable;
2
C-bus, unique START (S) and STOP (P) conditions
allowed
change
of data
STOP condition
Contactless reader IC
mbc621
P
MFRC523
© NXP B.V. 2010. All rights reserved.
mbc622
SDA
SCL
17 of 98

Related parts for MFRC52301HN1,151