ATTINY461-20PU Atmel, ATTINY461-20PU Datasheet - Page 181

Microcontrollers (MCU) 4kB Flash 0.256kB EEPROM 16 I/O Pins

ATTINY461-20PU

Manufacturer Part Number
ATTINY461-20PU
Description
Microcontrollers (MCU) 4kB Flash 0.256kB EEPROM 16 I/O Pins
Manufacturer
Atmel
Datasheets

Specifications of ATTINY461-20PU

Processor Series
ATTINY4x
Core
AVR8
Data Bus Width
8 bit
Data Ram Size
256 B
Interface Type
2-Wire/SPI/USI
Maximum Clock Frequency
20 MHz
Number Of Programmable I/os
16
Number Of Timers
2
Operating Supply Voltage
4.5 V to 5.5 V
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
3rd Party Development Tools
EWAVR, EWAVR-BL
Development Tools By Supplier
ATAVRDRAGON, ATSTK500, ATSTK600, ATAVRISP2, ATAVRONEKIT
Minimum Operating Temperature
- 40 C
On-chip Adc
11-ch x 10-bit
Program Memory Type
Flash
Program Memory Size
4 KB
Package / Case
PDIP-20
Package
20PDIP
Device Core
AVR
Family Name
ATtiny
Maximum Speed
20 MHz
Ram Size
256 Byte
Operating Temperature
-40 to 85 °C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2588E–AVR–08/10
While the lower bits in the address are mapped to words within the page, the higher bits address
the pages within the FLASH. This is illustrated in
required to address words in the page (pagesize < 256), the most significant bit(s) in the address
low byte are used to address the page when performing a Page Write.
3. Load Data Low Byte:
4. Load Data High Byte:
5. Repeat steps 2 to 4 until the entire buffer is filled or until all data within the page is
6. Load Address High byte:
7. Program Page:
8. Repeat steps 2 to 7 until the entire Flash is programmed or until all data has been
9. End Page Programming:
a. Set XA1, XA0 to “01”. This enables data loading.
b. Set DATA = Data low byte (0x00 - 0xFF).
c. Give XTAL1 a positive pulse. This loads the data byte.
a. Set BS1 to “1”. This selects high data byte.
b. Keep XA1, XA0 at “01”. This enables data loading.
c. Set DATA = Data high byte (0x00 - 0xFF).
d. Give XTAL1 a positive pulse. This loads the data byte.
loaded.
a. Set XA1, XA0 to “00”. This enables address loading.
b. Set BS1 to “1”. This selects high address.
c. Set DATA = Address high byte (0x00 - 0xFF).
d. Give XTAL1 a positive pulse. This loads the address high byte.
a. Give WR a negative pulse. This starts programming of the entire page of data.
b. Wait until RDY/BSY goes high.
programmed.
a. Set XA1, XA0 to “10”. This enables command loading.
b. Set DATA to “0000 0000”. This is the command for No Operation.
c. Give XTAL1 a positive pulse. This loads the command, and the internal write sig-
RDY/BSY goes low.
nals are reset.
Figure
18-4. Note that if less than eight bits are
181