CV500ETN01 Omron, CV500ETN01 Datasheet - Page 142
CV500ETN01
Manufacturer Part Number
CV500ETN01
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet
1.CV500ETN01.pdf
(285 pages)
Specifications of CV500ETN01
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
- Current page: 142 of 285
- Download datasheet (5Mb)
UDP Port Numbers for
FINS/UDP
Procedure for Using FINS/UDP
FINS/UDP Method
1.
2.
3.
4.
Make the basic settings.
Refer to SECTION 2 Startup Procedure in the Operation Manual Construction of Networks.
Make the settings in the Unit Setup.
With the CX-Programmer connected online, select the Ethernet Unit in the CX-Programmer's I/O
Table Window. Right-click, and select Unit Setup. Then make the following settings in the Unit
Setup Window.
Setup Tab
• Broadcast
• FINS/UDP port (Default: 9600)
• IP address table (for the IP address table method only)
Make the routing table settings and transfer them to each PLC. (See note.)
Set the routing tables with CX-Integrator, and transfer it to each PLC.
Create a ladder program that includes the SEND(090), RECV(098), and CMND(490) instructions.
Note
The UDP port number is the number for UDP to identify the application layer
(i.e., the FINS communications service in this case). When communications
are executed by UDP/IP, this port number must be allocated to the communi-
cations service.
The default setting for the FINS/UDP local UDP port number (i.e., the Ether-
net Unit's UDP port number) is 9600. To set another number, make the setting
for the FINS/UDP port using the Setup Tab in the Unit Setup.
At the Ethernet Unit, a UDP/IP frame received with a FINS/UDP port number
is recognized as a FINS frame.
Routing tables are required in the following situations:
It is not necessary to set routing tables if one Communications Unit is
mounted to the PLC and the nodes are connected as one network.
• When communicating with a PLC or computer on another network (e.g.,
• When multiple Communications Units are mounted to a single PLC (i.e.,
• When routing tables are used for one or more other nodes on the same
remote programming or monitoring using FINS messages or a CX-Pro-
grammer).
CPU Unit).
network.
Section 6-2
117
Related parts for CV500ETN01
Image
Part Number
Description
Manufacturer
Datasheet
Request
R
Part Number:
Description:
G6S-2GLow Signal Relay
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Compact, Low-cost, SSR Switching 5 to 20 A
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet:
Part Number:
Description:
Manufacturer:
Omron Corporation
Datasheet: