Specifications of CV500ETN01

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Command/Response Reference
Parameters
Test Data (Command,
Response)
Precautions
Response Codes
7-3-5
Command Block
Response Block
Parameters
Times Received
(Response)
Response Codes
7-3-6
164
BROADCAST TEST RESULTS READ
BROADCAST DATA SEND
This command specifies the data to be sent to the specified nodes. Up to
1,998 bytes can be specified. The response sends back data identical to the
data specified in the command. An abnormality is assumed if the data
returned in the response differs from the test data sent.
The test destination node is the destination node specified in the CMND(194)
instruction operands.
Always specify the unit address of the Ethernet Unit in the CMND(194)
instruction.
Reads the results (number of times data received) of the broadcast test.
The number of times the data has been received normally during the broad-
cast send test is returned as a hexadecimal number. The number of times
received is cleared each time the result is read.
Sends test data simultaneously to all nodes on the network.
Command
0000
1001
1002
0000
1001
Command
08 02
08 02
Response code
code
Response code
code
Response
code
received
Times
Normal
Command too large
Command too small (No test data)
Normal
Command too large
Description
Description
Section 7-3