Command/Response Reference
Results Storage Area Response Codes
7-3-17 TCP CLOSE REQUEST
Command Block
Response Block
Results Storage Format
Parameters
Socket Option (Command)
TCP Socket Number
(Command)
180
Note
These errors occur only in large multilayered networks.
Requests processing to close a TCP socket. Other processing being carried
out is forcibly ended and a code is recorded in the results storage area.
The socket option specified as 1 byte. The setting is not valid for this com-
mand. Set to 0.
The TCP socket number to be closed specified as 1 byte between 1 and 8.
0000
0020
003E
0042 (see note)
0044 (see note)
0045 (see note)
004B (see note)
004E (see note)
004F (see note)
0051 (see note)
0053 (see note)
0081
Response code
Command
Command
27 14
27 14
Response code
code
code
Socket option
Response
code
TCP socket number
Results storage area
Normal
Connection to the remote socket was broken during transmis-
sion (EPIPE).
Internal buffer cannot be reserved due to high receive load
(ENOBUFS).
An error occurred (EMSGSIZE).
Received ICMP data (ENOPROTOOPT).
A communication error occurred with the remote node
(ECONNABORTED).
A communication error occurred with the remote node
(ECONNRESET).
A parameter error occurred at the remote IP address
(ENETUNREACH).
Received ICMP data (EHOSTDOWN).
A parameter error occurred at the remote IP address
(EHOSTUNREACH).
A communication error occurred with the remote node
(ETIMEDOUT).
The specified socket was closed during transmission.