7-3-10 UDP RECEIVE REQUEST
Command Block
Response Block
Results Storage Format
Parameters
Socket Option (Command)
UDP Socket Number
(Command)
Results Storage Area
(Command)
168
Requests that data be sent from a UDP socket.
The socket option specified as 1 byte. The setting is not valid for this com-
mand. Set to 0.
The UDP socket number to receive data specified as 1 byte between 1 and 8.
The area in which the results of the command execution are stored. The first
byte specifies the memory area and data type (variable type). The 2nd to 4th
bytes specify the beginning address of the results storage area. Refer to
page 158 for details about the variable types and addresses that can be spec-
ified.
0000
003E
0049
1002
1100
1101
1103
220F
2211
Command
Response
Command
27 02
27 02
Response code
Response code
code
code
code
Socket option
Response
Source IP address
code
UDP socket number
Results storage area
Normal
Internal buffer cannot be reserved due to high receive load
(ENOBUFS).
Duplicate UDP port number (EADDRINUSE).
Command too small
UDP socket number is out of range.
Local UDP port number is 0.
The variable type for the results storage area is out of range.
Non-zero bit address specified for the results storage area.
Specified socket is already open or is being closed.
High traffic at Unit; cannot execute service.
Source UDP
port number
of reception
Number of
Number
reception
bytes
bytes
Timeout
value
Description
Description
Received bytes
Received data